Temperature test chamberCTS
TSR-30/1000
Temperature test chamber
CTS
TSR-30/1000
Condition
Used
Location
Borken 

Show images
Show map
Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A149-26978
- Reference number:
- 23988
- Update:
- 15.11.2024
Description
CTS
Type: TSR-30/1000
Water-cooled
The type designation of the CTS enclosure series is made up as follows:
z. e.g. type TSR -30/1000
1) T means: Temperature
2) S means: stress screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liter test chamber volume
Technical performance data:
A) TSR-30/1000 basic device without hose connections,
i.e. when used as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Air volume flow
approx.2000m³/h
B) TSR-30/1000 basic unit with hose connections,
for connection to an external test room provided by the customer
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K in time
Average rate of temperature change,
measured with short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range from +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment,
measured with short-circuited circuit
Attention: The external test chamber provided by the customer must be absolutely tight and appropriately insulated,
any feed-throughs must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, fully hermetic
Infinitely variable capacity adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, door hinge on the left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf 35 kg
Total load with max. shelf load 100 kg
Test area lighting: Halogen lamp 20 W, 12 V
Control:
- 32 bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Kdedperivfcefx Ad Neg
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Type: TSR-30/1000
Water-cooled
The type designation of the CTS enclosure series is made up as follows:
z. e.g. type TSR -30/1000
1) T means: Temperature
2) S means: stress screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liter test chamber volume
Technical performance data:
A) TSR-30/1000 basic device without hose connections,
i.e. when used as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Air volume flow
approx.2000m³/h
B) TSR-30/1000 basic unit with hose connections,
for connection to an external test room provided by the customer
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K in time
Average rate of temperature change,
measured with short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range from +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment,
measured with short-circuited circuit
Attention: The external test chamber provided by the customer must be absolutely tight and appropriately insulated,
any feed-throughs must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, fully hermetic
Infinitely variable capacity adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, door hinge on the left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf 35 kg
Total load with max. shelf load 100 kg
Test area lighting: Halogen lamp 20 W, 12 V
Control:
- 32 bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Kdedperivfcefx Ad Neg
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Sonsbeck
7,609 km
Tensile Testing Machine-Universal Testing Machine
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Listing
Germany
7,623 km
Salt spray chamber Corrosion chamber
KöhlerHKT 500 WTG
KöhlerHKT 500 WTG
Listing
Borken
7,623 km
Climatic test chamber
Feutron3702/06
Feutron3702/06
Listing
Borken
7,623 km
Climate chamber
WEISSWK1-1000/70
WEISSWK1-1000/70
Listing
Borken
7,623 km
Shaker system with amplifier
LDSV895-440 HBT900C + SPA50K
LDSV895-440 HBT900C + SPA50K
Listing
Borken
7,623 km
Environmental test chamber -70°C - +180°C Humidity
ThermotronSM-8-8200
ThermotronSM-8-8200
Listing
Borken
7,623 km
Shock test chamber +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
VötschVT 7012 S2 (6603)
Listing
Borken
7,623 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
VötschVT 7012 S2
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
Listing
Borken
7,614 km
Walk-in climate test chamber
VötschVSKZ 04/120/S
VötschVSKZ 04/120/S
Your listing has been deleted successfully
An error has occurred