Laser cleaning deviceClean Laser
CL 100G-BRP
Laser cleaning device
Clean Laser
CL 100G-BRP
DDP ONO plus VAT
€80,000
Condition
New
(fully functional)
Location
Wiener Neudorf 

Machine data
- Machine type:
- Laser cleaning device
- Manufacturer:
- Clean Laser
- Model:
- CL 100G-BRP
- Condition:
- new
- Functionality:
- fully functional
- Operating hours:
- 5 h
Price & Location
DDP ONO plus VAT
€80,000
- Location:
- Wiener Neudorf, Austria

Call
Technical details
- Control cabinet width:
- 800 mm
- Control cabinet height:
- 1,700 mm
- Input voltage:
- 400 V
- Input current:
- 16 A
- Type of input current:
- AC
- Equipment:
- documentation/manual
Details about the offer
- Listing ID:
- A223-45012
- Update:
- 16.07.2026
Description
Individual System L25-2203
cleanCABINET CL 100G-BRP
Complete laser system for integration as
individual components, consisting of the
following modules:
- Special item: Low-power laser production
Laser system CL100G-BRP, diode-pumped laser
Wavelength 1064nm, operating mode: pulsed (ns)
Average laser power: P = 100 W +/- 3%
Prepared for pilot laser, 19" rack-mount design
Comparable to 2003836
Special configuration: 10m fiber length, extended pulses
- 2D optics system Stamp 10 for LP lasers (CL12BRP-CL100BRP)
Automated 2D optics with connection for back-reflection
protection (BRP) and 90° deflection, max. working area:
120mmx120mm (=160mm)/290mmx290mm (F=420mm)
Focus diameter depends on the focal length of the optics
Included components:
2D optics system Stamp 10
90° connection
Control electronics
Cable set
cleanSTUDIO/cleanCONTROL license for 2D optics
(without axis system support)
RTC
- Focusing lens f=254, fully quartz,
High grade, working area approx. 150mmx150mm
Minimal focus shift
- BG protective glass slide STAMP 10/14 F420
Quick-change slide for mounting on the Stamp14 with
locking monitoring
- Alignment laser for low-power lasers (LP)
(CL12G-CL-500G) The alignment laser allows
monitoring the beam incident point
on the component surface. Installation in the
beam source, coupling into the fiber transmission,
wavelength = 660nm, power: P = 0.5 mW
(min. 0.2mW, max. 1.0 mW)
Hodpfx Ajzl Slyochjnp
- Decentralized laser source housing W/L
Housing for the CL100 beam source including air-water heat exchanger
2kW, see 3D-CAD file.
- GS control cabinet 1-1600 (CL12G-CL100G)
Update: 32m cable length
Laser housing in control cabinet design, type 1/1600
for low-power laser systems (CL12G-CL100G) consisting of:
cabinet frame with Rittal double-bit lock, structural
powder coating, RAL 7035S, optional
air conditioning
Installed on heavy-duty rollers, braked,
250kg load capacity,
Fiber/cable feed-through through the roof, power supply via Harting Han6, left side panel,
safety circuit "Performance Level D",
installation position of laser and fiber outlet variable,
emergency stop, key switch for starting and
main switch in the front door, tested according to DGUVV3
Dimensions: HxWxD:
1600x600x800mm
requires operation visualization, cooling capacity
adjusted to the ambient temperature at the installation location
WITHOUT AIR CONDITIONING as it is only for accommodating HMI,
PC and PL-D technology
including PLD technology
PLD item as plug-in module (see below
or alternatively wired in the control cabinet
- BG housing 19" 2U PLD
PLD plug-in for safe shutdown of
low-power laser systems, installed in
19" housing - 2U for use with laser systems
- VS-OPT Ethercat copper (MP/HP 2D)
Ethercat interface for mid and high-power (2D)
systems - fieldbus interface - 2D
interface - Ethercat copper - cleanSTUDIO
protocol
- IPC 19" 1U
- Touch panel standard 17-inch with HDMI+DP-VGA
- Keyboard with trackball DE
QWERTZ keyboard with trackball (DE)
The listing was translated automatically. Translation errors are possible.
cleanCABINET CL 100G-BRP
Complete laser system for integration as
individual components, consisting of the
following modules:
- Special item: Low-power laser production
Laser system CL100G-BRP, diode-pumped laser
Wavelength 1064nm, operating mode: pulsed (ns)
Average laser power: P = 100 W +/- 3%
Prepared for pilot laser, 19" rack-mount design
Comparable to 2003836
Special configuration: 10m fiber length, extended pulses
- 2D optics system Stamp 10 for LP lasers (CL12BRP-CL100BRP)
Automated 2D optics with connection for back-reflection
protection (BRP) and 90° deflection, max. working area:
120mmx120mm (=160mm)/290mmx290mm (F=420mm)
Focus diameter depends on the focal length of the optics
Included components:
2D optics system Stamp 10
90° connection
Control electronics
Cable set
cleanSTUDIO/cleanCONTROL license for 2D optics
(without axis system support)
RTC
- Focusing lens f=254, fully quartz,
High grade, working area approx. 150mmx150mm
Minimal focus shift
- BG protective glass slide STAMP 10/14 F420
Quick-change slide for mounting on the Stamp14 with
locking monitoring
- Alignment laser for low-power lasers (LP)
(CL12G-CL-500G) The alignment laser allows
monitoring the beam incident point
on the component surface. Installation in the
beam source, coupling into the fiber transmission,
wavelength = 660nm, power: P = 0.5 mW
(min. 0.2mW, max. 1.0 mW)
Hodpfx Ajzl Slyochjnp
- Decentralized laser source housing W/L
Housing for the CL100 beam source including air-water heat exchanger
2kW, see 3D-CAD file.
- GS control cabinet 1-1600 (CL12G-CL100G)
Update: 32m cable length
Laser housing in control cabinet design, type 1/1600
for low-power laser systems (CL12G-CL100G) consisting of:
cabinet frame with Rittal double-bit lock, structural
powder coating, RAL 7035S, optional
air conditioning
Installed on heavy-duty rollers, braked,
250kg load capacity,
Fiber/cable feed-through through the roof, power supply via Harting Han6, left side panel,
safety circuit "Performance Level D",
installation position of laser and fiber outlet variable,
emergency stop, key switch for starting and
main switch in the front door, tested according to DGUVV3
Dimensions: HxWxD:
1600x600x800mm
requires operation visualization, cooling capacity
adjusted to the ambient temperature at the installation location
WITHOUT AIR CONDITIONING as it is only for accommodating HMI,
PC and PL-D technology
including PLD technology
PLD item as plug-in module (see below
or alternatively wired in the control cabinet
- BG housing 19" 2U PLD
PLD plug-in for safe shutdown of
low-power laser systems, installed in
19" housing - 2U for use with laser systems
- VS-OPT Ethercat copper (MP/HP 2D)
Ethercat interface for mid and high-power (2D)
systems - fieldbus interface - 2D
interface - Ethercat copper - cleanSTUDIO
protocol
- IPC 19" 1U
- Touch panel standard 17-inch with HDMI+DP-VGA
- Keyboard with trackball DE
QWERTZ keyboard with trackball (DE)
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Last online: Yesterday
Registered since: 2026
1 listing online
Send inquiry
Telephone & Fax
+43 2236 ... show
Your listing has been deleted successfully
An error has occurred