Used Material testing for sale (495)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing

7,623 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Cslipform Rihs I Hogt
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Celipferu Dzuj I Hsgt
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Cgjljgkaibjipf I Hjt
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax

Find out now
+49 201 857 86 180
+49 201 857 86 180
Create listing
*per listing / month
Listing

7,623 km
Temperature shock chamber
EspecTSA-201 SW
Call
Condition: excellent (used), Espec Temperature Shock Chamber
Here we offer you an Espec temperature shock chamber.
Thermal shock environmental chamber (cold load: -65° to 0°C). Conventional thermal shock chambers with three zones can be quite large because three separate chambers are used.
The TSA series has only one chamber, significantly reducing its size. Instead, it circulates cold, hot or ambient air as needed.
The conditioned air can be precooled or preheated beyond the set point, allowing for faster recovery to the desired condition after transfer.
Espec Temperature Shock Chamber Water Cooled TSA-201S SN: 153000154
Hot chamber: +60 to 200°C Cold chamber: -70 to 0°C
Working temperature: 0-40°C
System: two zone or three zone test by flap switching.
Performance:
Test range:
High temperature. Exposure range: +60 to +200°C
Low temperature. Exposure range: -70 to 0°C
Temperature variation ±0.5°C
Hot chamber:
Temperature Heating time: ambient temp. to +200°C within 15 min.
Cooling chamber:
Temperature Pulldown time: ambient temp. to -75°C within 45 min.
Temperature recovery: within 10 min.
Inner dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Power supply: 380/400/415V AC 50Hz: 70 A
Cjlipfeg S Ugke I Hegt
Refrigerant: R404/R23
Weight: approx. 1400 kg
Type: Espec Model: TSA-201 SW
For you as a buyer, the following information for your safety!
The following points are checked on our offered chambers in advance.
Listing

7,623 km
Vibration test system
RMSSW 3006 mit TGA 1500
Call
Condition: excellent (used), RMS Vibration Test System
Here we offer you a RMS electrodynamic vibration test equipment.
RMS Vibration Test System
Vibration exciter SW 3006
Power amplifier TGA 1500
Technical data:
Sine:3,7 kN
Noise:3,7 kN
Shock:3.7 kN
Displacement pk-pk:26 mm
Speed: 0.9 m/s
Acceleration: 80 g
Cooling: air cooled
Condition: used / used
Untested! Tests were not possible
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Cslipfohyly Ro I Hsgt
Further questions we can answer on the phone for you.
Written order possible by email or fax
Discover more used machines
Listing

7,623 km
Chamber convection oven
EliogKU 300/09-06-06/2
Call
Condition: excellent (used), Eliog
Here we offer you a chamber air circulation furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
Cjlipfeifkiij I Hegt
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 13 kVA
Heating power: 12 kW
Nominal temperature: 300°C
weight: 400 kg
Type: KU 300/09-06/2 K1051071
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Emission test chamber 480 liters
VötschVCE 1000/S +20°C bis +130°C
Call
Condition: excellent (used), Here we offer you a Vötsch emission chamber.
Water cooled
Test chamber volume 1000 liters (usable) (916) liters Adjustment tank 480 liters
Performance for temperature tests:
Temperature range +20°C to +130°C
Temperature deviation temporal K ±0.1 to ±0.3
Temperature deviation spatial K ±0,5
Temperature gradient K 1
Temperature rate of change:
Cooling K/min 0.3
Heating K/min 0,4
Performance for climatic tests:
Carrier gas conditioning with climatic module
according to the evaporation principle
Colipfei Hbyle I Hsgt
Temperature range +20°C to +130°C
Humidity range 5 to 95%
Dew point range +5°C to +60°C
Humidity deviation in time % ±1 to ±3
Carrier gas exchange rate 0.1 to 1.8 chamber volume per hr.
Capacity range for desorption
Desorption temperature up to max. +240°C, adjustable
Test chamber surface temperature between +220°C and +240°C
Purge rate max. 4 m³/h
Test chamber dimensions: Width 750 mm Depth 1630 mm Height 750 mm
test chamber door 670 x 670 mm
Outer dimensions: Width 1350 mm Height 2950 mm Height 2050 mm
rated current 32 A
nominal power 19,0 kW
Electrical connection 3/N/PE AC 400V ± 10% 50Hz
Weight 1200 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VCE 1000/S
Condition: used / used
Scope of delivery: (See picture)
Sale ex location
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Analytical drift detector
Oxford InstrumentsINCAx-act
Call
Condition: excellent (used), Oxford Instruments
Here we offer you an INCAx-act Analytical Drift Detector.
Microanalysis of elements including boron and above
Operating temperature
Normal mode 10-25 degrees
Operating temperature
extended mode 10-30 degrees
Storage temperature
Cjlipfjhx Nchs I Hjgt
-25 to 40 degrees and 8 to 80% humidity non-condensing
Operating humidity
Listing

7,623 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer Weiss temperature chamber.
Converted to R452a
Weiss temperature chamber air cooled
Temperature range: from - 30°C to 180°C
Cgeljic Rgfjipf I Het
Temperature change rate cooling 1,6 K/min
Temperature change rate heating 2,1 K/min
Test chamber dimensions: Width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: Width 800 mm x depth 1500 mm x heights 1800 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4,9 kW Rated current 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For you as a buyer the following information for safety!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature test chamber ex protected
CTS-30°C bis +80°C T-30/950 Ex/I
Call
Year of construction: 2011, Condition: excellent (used), Here we offer you CTS temperature test chamber.
Control-32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of the setpoints
Error messages in plain text
Interface RS 232
Free switching channels for on-site test material control
Temperature tests:
temperature range -30°C to +80°C
temperature deviation ±0,3 K temporally
Temperature change rate
heating 2 K/min
Cooling 1.5 K/min to -10°C
Heat radiation approx. 1000 W at +20°C
approx. 200 W at -25°C
Data for gas supply:
Temperature range: -25°C to +55°C
Temperature deviation: ±0.25 K to the test space
Temperature change rate measured on average at a gas flow of 10 Nm³/h: at least as fast as the test chamber
Data for the gas return:
Temperature range: +18°C to +30°C
Temperature deviation: ±0.25 K to the test chamber
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with the large purge volume N2 until the
oxygen content is less than 3%. After that, the system switches to a base load (approx. 10% of the large flush volume).
is switched over.
The nitrogen flow rate of the base load is measured with a flow meter, displayed and monitored by a limit switch.
and monitored by means of a limit switch.
The O2 monitoring system continuously extracts from the test chamber via a flashback arrestor
gas from the test chamber via a flame arrester and passes it over an O2 sensor that monitors the residual oxygen content of the extracted air.
The gas is then returned to the test chamber via a second flashback arrestor.
test chamber. The exhaust pump is monitored by a volumetric flow meter. Further details can be found
can be found in the Dräger operating instructions in the appendix.
The gas device is currently out of service!
The technical data refer to an ambient temperature of +25 °C,
Nominal voltage 400V , without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 950 liters
Test chamber dimensions height approx. 700 mm / width approx. 900 mm depth approx. 1500 mm
External dimensions height approx. 2400 mm / width approx. 1270 mm depth approx. 3125 mm
Operating data:
Electrical connection 400V+6/-10 %, 3/N,50 Hz
rated power 21,6 kW
rated current: 36,5 A
Protection class IP 54
condensate drain pressureless R 1/2" female thread
Sound pressure level < 62 dB(A)
(according to DIN EN ISO 3744
measured at 1m distance from front)
weight: approx. 1500 kg, control cabinet approx. 300 kg
external refrigeration unit
refrigerant R404A / R23
Type: T-30/950 Ex/I
For you as a buyer for safety the following information!
Cgslipoihb Amof I Het
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Shaft meter
MahrHelio-Pan II 700
Call
Condition: excellent (used), Mahr
Here we offer you a Helio-Pan II.
max. workpiece weight 30 kg at center height 100 mm
80 kg with center height 150 mm
measuring range length 0 mm to 700 mm
measuring range outer diameter 0 mm to 120 mm
max. throwing distance to be measured 100 mm
tip height 100 mm
Measuring blades probe and caliper 1 mm x 5 mm
Celisi Ezh Uspf I Hegt
Dimension (W x D x H)
machine 2060 mm x 920 mm x 1750 mm
controller box 600 mm x 800 mm x 2200 mm
Weight approx. 900 kg
Electrical power 230 V / 1200 W / 50 Hz
Air pressure 6 bar
Type: Helio-Pan II 700
Scope of delivery: (See picture)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

7,623 km
Temperature shock test chamber
Weiss130 Liter TS 130 50010
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 sec.
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Cgolipon Aq Ufef I Hjt
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
Cjlipf Ioqnutmo Hjgt
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Celipfsrbiyfo I Hsgt
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Salt spray test chamber Climate change test
WeissSC / KWT-1000 1000 Liter
Call
Condition: excellent (used), White
Type: SC / KWT - 1000
Technical data:
Salt spray mist test MIN 5 K > Tu MAX +50°C
Condensation water test MIN 5 K > Tu MAX +45°C
Humidifier MIN 5 K > Tu MAX +75°C
Temperature constancy
The temperature deviation over time is ±1 K
Dimension with hood:
Csljrh Dmqoipf I Hegt
Test chamber: H 1190 mm x W 1650 mm x D 570 mm
Dimensions without hood:
Test area: H 740 mm x W 1650 mm x D 570 mm
Dimensions with hood:
Outside: H 1370 mm x W 2730 mm x D 800 mm
Dimensions without hood:
Outside: H 920 mm x W 2730 mm x D 800 mm
Capacity approx. 700 - 1130 liters
3/N/PE AC 400V ±10%50Hz
Rated power 4 KW Rated current 7.5 A
Weight: 180 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Vacuum drying oven
HeraeusVT 6025 200°C
Call
Condition: excellent (used), Heraeus
Type: VT 6025
Heraeus Vacutherm vacuum drying oven
Specification jacket heating VT 6025
Temperature (metric) 200 °C
Dimensions, inside (W x D x H): 300 x 307 x 275 mm
External dimensions (W x D x H): 480 x 450 x 600 mm
Electrical requirements 230 V, 50/60 Hz
Frequency 50/60 Hz
Capacity (metric) 25 l
Heating jacket type without inert gas connection
Voltage 230 V 1.3 kW, 5.9 A
Weight: 58 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Cjlipf Isrknago Hjgt
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate chamber 38m³ Sunlight simulation
WeissWK 40'/40-120/So -40° bis +120°C
Call
Condition: excellent (used), Internal dimensions (net) H approx. 2150 mm W approx. 3000 mm D approx. 6000 mm
Air circulation system (on chamber rear wall) Width approx. 800 mm
External dimensions with machine unit and without control cabinets
Height approx. 3360 mm Width approx. 3320 mm Depth approx. 8620 mm
Machine room, attached to the rear wall of the chamber
Height approx. 2340 mm Width approx. 3320 mm Depth approx. 1500 mm
Electrical control cabinet, mounted on the side of the base frame
Height approx. 2340 mm Width approx. 2400 mm Depth approx. 600 mm
Chamber door (double-leaf)
Height approx. 2150 mm Width approx. 3000 mm
Pedestrian door (single-leaf)
Height approx. 1900 mm Width approx. 900 mm
Lighting (switch next to pedestrian door)
4 incandescent lamps 60W
Feed-throughs 4 pcs. 125 mm ∅
Floor load capacity
30,000 N/m² (surface load);
2,500 N per polyamide wheel Ø100mm;
4,000 N for a wheel with 4 cm²
Ceiling opening (clear dimensions of the lower disk)
Length approx. 600 mm Width approx. 700 mm
Quantity: 10 pieces
Ceiling load: 10 SoSi radiators + 1 person 90 kg
Working temperature range:
Temperature range -40 °C ... +120 °C (discontinuous)
Cooling speed:
approx. 1 K/min. linear from 80°C to -40°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
At temperatures < (-20°C) the recirculated air volume is reduced by 50%.
(e.g. PV 1200)
Heating speed:
approx. 1 K/min. linear from -30°C to +90°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
(e.g. PR 308.2)
Test specimen mass: 600 kg aluminum (vehicle - partial body)
Working range climate without sunlight simulation:
Temperature range: +10 °C ...+95 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Temperature constancy: ≤ ± 2 K (spatial)
Humidity range: 20 ... 80 % r.h., without thermal load
Dew point temperature range: -2 °C ...85 °C without thermal load
Climate working range with sunlight simulation:
Temperature range: +23 °C ...+50 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Humidity range: 20 ... 70 % r.h., with thermal load
Dew point temperature range: -2 °C ...43 °C without thermal load
Thermal load of the SoSi: Max. 10 kW
Temperature and humidity instances:
Temperature
The following maximum deviation is specified for the temperature in the climate and temperature range
(including measurement uncertainty and with test material):
Blow-out after 15 minutes: ±1K
Intake after 45 minutes: ±1.5K (external sensor)
Humidity
For the relative humidity at the operating point 80°C / 80% r.h.
the following maximum deviation (including measurement uncertainty and with test material) is specified:
Blow-out after 30 minutes: ±3% r.h.
Intake after 60 minutes: ±3% r.h. (external sensor)
Cslipetrmm Nef I Hjgt
Connection and consumption data:
Air-cooled refrigeration unit, maximum air temperature +38°C
Refrigerant R 404 A and R23
Water supply for humidifier:
Approx. 40 l/h = 40 kg/h installed steam output,
demineralized water, electrical conductivity 5-20 μS/m
Mains connection: 400 V; 3 PH + N + PE; 50 Hz
Connected load: 250 kVA, 350 A
Connection according to VDE 0110 group 2: 5x185 mm2 CU
On-site fuse protection: 355 A
Air circulation volume (FI-controlled): 24,000 to 28,000 m³/h
FC basic setting: 50% (achievement of the parameters)
Technical data solar simulation:
Manufacturer: BF Engineering GmbH
Type: G-BEM-1119
Number of lights: EPSU 2 x 2k_HQI
Ballast: 10
Ignitor: IGC-4k-03
Light source: OSRAM HQI 2000W High Flux
3〜/ N / PE
Listing

7,623 km
Cleanroom workbench
HeraeusHA 2472 BS
Call
Condition: excellent (used), Heraeus
Cslipevyd Adef I Hogt
Type: HA 2472 BS
Cleanroom workbench
for installation and operation in laboratories
Interior dimensions: 1,800 mm x 580 mm x 830 mm (length x depth x height)
Lighting, gas connection
Condition: used
Scope of delivery. (See pictures)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,623 km
Walk-in climate simulation cell
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation cell
System structure:
The system consists of the following main components:
Walk-in, insulated cell
Air treatment room
Humidification system
Machine room
Switch cabinet
Technical data:
Performance range for temperature testing:
Temperature range -40...+140°C
Temperature constancy, in the supply air: (time-wise) ≤ ± 0.5°C
without them. Test room load according to (DIN 50011 Τ13) EN 60068
Temperature constancy, in the supply air: (spatial) ≤ ± 1.0°C
without thermal test room load according to (DIN 50011) EN 60068
Heating rate (according to DIN 50011) approx. 2.0 K/min
without thermal test room load (according to DIN 50011)
EN 60068) or test material in the temperature range of -30°C...+85°C
Cooling rate (according to DIN 50011) approx. 2.0 K/min
without thermal test room load (according to DIN 50011)
EN 60068) or test material in the temperature range of -30°C...+85°C
Performance range for climate test:
Temperature range +10...+90°C
Humidity working range 10...approx. 95% r.H
without thermal test room touch
Dew point temperature range +5...+89°C
without thermal test room touch
Humidity constancy (in the supply air) (time-wise) ≤ ± 2.5% r.H
measured in the supply air
Performance range for climate testing with heat compensation
Temperature range + 15...+ 80°C
Humidity 15...approx. 80% r.H
without thermal test room load
with max. 16 kW heat compensation
Dew point temperature range +10...+74°C
without thermal test room touch
Dimensions: test room (WxDxH) approx. 2260 x 4648 x 2260 mm
Dimensions: external dimensions (WxDxH) approx. 2660 x 6460 x 2800 mm
clear doorway test room door (W x H) 2260 x 2260 mm
climate module KB 127 (W x D x H) 1700 x 800 x 1400 mm
switch cabinet (W x D x H) 800 x 500 x 2000 mm
design:
air flow: supply air: perforated sheet on the rear wall, in the ceiling area
exhaust air: perforated sheet on the rear wall, in the floor area
temperature control:
direct cooling by evaporation of
refrigerant in a finned heat exchanger:
heating with electric resistance heater
dehumidification:
direct dehumidification by evaporation of
refrigerant in a heat exchanger
interior paneling: stainless steel
outer paneling: sheet steel, galvanized, plastic-coated
floor design: stainless steel,
floor load 15000 N/m²
wheel load (contact surface ≥4cm²) 1500 N/wheelDoor: double-leaf door, stainless steel, painted on the outside with
viewing window (WxH) l000xl000 mm
Test room lighting: 4 spotlights of 500 W each
Insulation Two-layer insulation, 80 mm PUR foam,
120 mm mineral wool
Refrigerator (1 piece) Bltzer 6G-30.2Y
Celipf Isvx S Hhe Hjgt
Refrigerant, R449A!
Refrigeration machine oil SEZ 32
Steam humidifier (1 piece) EDB 40Color:
Cell RAL9010, white
Door RAL9010, white
Machine unit RAL 7032, pebble gray
Control cabinet RAL 7032, pebble gray
Mass:
Total system
approx. 4900 kg
Machine set KB 127 approx. 750 kg
Control cabinet approx. 120 kg
Humidification system approx. 64 kgConnections:
Nominal voltage 400 V +6%/-10% 3/PA 50Hz
Nominal power 95 kW
Nominal current 150 A
Listing

7,623 km
Resonance testing machine
SincoTecPower Swingly 20 kN EXCITING MOT
Call
Condition: used, SincoTec
Type: Exciting Mot
Resonance test bench POWER SWINGLY 20 kN
The resonance test bench POWER SWINGLY BigTable is designed as a two-mass oscillator.
It consists of an oscillating head excited by a frequency-controlled asynchronous motor using an unbalance motor,
which is arranged in the upper part of the machine and generates the dynamic amplitude.
The oscillating head is supported by pre-tensioned helical compression springs on the upper crossbeam and is guided centrally.
The medium-load drive is arranged in the lower part of the machine and applies the static preload
with the help of a gear motor via a spindle drive.
The sample space is located above the clamping table and is limited at the top by the adjustable crossbeam.
The test bench is controlled by the EXCITING MOT control system.
The complete control electronics for the control system are housed in an industrial PC cabinet.
The control cabinet is made of powder-coated sheet steel and meets protection class IP 50 according to EN 60529.
Technical data:
General data test bench:
Total height of test bench 1840 to 2240 mm
Height of machine table 1030 mm
Width of test bench 800 mm
Depth of test bench 1500 mm
Height of sample chamber max. 600 mm (without force transducer)
Free column passage 550 mm
Maximum force amplitude 10000 N
Maximum total force ±20000 N
Maximum vibration path ±5 mm
Test frequency 30 to 110 Hz
Accuracy of the measuring sensors min. Class 1 (according to DIN EN 10002-3)
Weight of test bench approx. 1880 kg
Max. weight of clamping device 150 kg
General data Control cabinet:
Total height of control cabinet 1900 mm
Height of table top 1080 mm
Width of control cabinet 650 mm
Depth of control cabinet 700 mm
Weight of control cabinet 152 kg
Color RAI 9006 (white aluminum), table top midnight
Conditions for the installation location:
Space requirement 2.5 x 2.5 m
Required ceiling height 2.8 m
Floor load capacity 170 N/cm²
Power supply 400 V / 50 Hz (clockwise rotating field)
Connection plug CEE socket, 2-pole, 16 A
Fuse 16 A
Connection and ambient conditions
Mains conditions:
Voltage 400 V rotating current with ΜΡ conductor and protective earth, clockwise rotating field
Cjlipsvx Su Sof I Hogt
Voltage fluctuations < ± 10%
Short-term dips < 20 ms
Limits for continuous interference Radio interference level A according to VDE0871
Frequency 50 Ηz ± 1%
Protective earth Earthing resistance < 0.3 Ω
Model: POWER SWINGLY MOT
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,623 km
Carbon-sulfur analysis
Leco C 230
Call
Condition: used, Leco
LECO C230 CARBON ANALYZER
Carbon analyzer C230
The LECO C230 carbon analyzer is a microprocessor-based,
software-controlled instrument for measuring the carbon and sulfur
sulfur content in metals, ores, ceramics and other inorganic
inorganic materials. The C230 uses an induction furnace
and measures carbon by infrared absorption.
The infrared (IR) source consists of nichrome wire, which is heated by
heated to 8500 °C by resistance heating. The IR source
emits visible energy and all wavelengths of the infrared spectrum
Carbon dioxide can be used for the description; the same principle applies to sulphur detection.
Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum.
within the IR spectrum. Energy from the IR source is absorbed,
when the gas flows through the cell, preventing it from reaching the IR detector.
An IR cell is used both as a reference and for measurement.
Total carbon in the form of carbon dioxide is detected continuously and simultaneously.
The initial reference level or baseline for the detector is set by passing oxygen through the cell.
established by passing oxygen through the cell to drive out residual atmospheric gases.
Technical data:
Gas required:
Carrier gas: Oxygen 99.5 % pure, 40 psi
Pneumatic gas: Compressed air, nitrogen or argon, 40 psi (2.76 bar),
Source must be free of oil and water Gas flow (based on nominal analysis time)
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulator
Oxygen: 501-291 O 2 pressure regulator
Compressed air: 766-036 Compressed air regulator
Inert gas: 764-216 Inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data transmission: Included
Data storage
Without PC: 10 sample weights, 50 responses, 5 methods
Without PC: Internal membrane /External optional display
Without PC: Liquid crystal (16 x 26 characters)
Power requirement
Determinator: 230 Ṽ̃̃, ± 10 %, 50/60 Hz,
Single-phase, 15 amps max.
Operating current: 12 A
Standby current: 4 A
Condition: gebraucht / used
Scope of delivery: (see picture)
Cgelsu Ndyxeipf I Het
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Werktuigen

Listing

7,623 km
Mass spectrometer
SPECTRO AMETEK Spectromaxx
Call
Condition: used, Spectro
Type: SpectroMaxX LMD08 / LMX08 Date: 24.07.2020
Full analysis with the stationary spark spectrometer SpectroMaxX:
With the help of the spark spectrometer, the alloy contents and accompanying elements of macroscopic solid samples can be
can be determined with high precision down to the ppm range.
Different analysis methods are available for the base materials iron, aluminum, magnesium, copper, nickel, titanium and lead,
measuring methods adapted to the relevant alloy families are available.
Advantages:
Fast analysis within a few seconds
Highly accurate spectral analysis including C and N
Cgslipfju S Ahqe I Het
Compact design (table-top device)
Areas of use / application:
Testing the chemical composition of 31 ferrous and non-ferrous metals
Composition of 31 ferrous and non-ferrous metals
metals, nitrogen and other elements
Description of the system:
Open spark stand for high sample throughput
Wide range of sample geometries possible
Simple change of base
The following elements are available as a base: Al, Cu, Fe, Mg, Ni, Ti, Pb
The analyzable elements and concentration levels depend on the methods available for the respective base element
Usable wavelength range 170-670 nm
Output of measured values in concentrations or intensities
Selectable output units (%, ppm)
Output of statistical characteristic values (mean value, RSD)
SPECTROMAXx LMX08
Technical specifications:
CCD optics:
High-resolution CCD multi-detectors
Stabilized against temperature fluctuations
Effective wavelength range: 140-670 nm, the applicable and configured wavelength range is
wavelength range depends on the customer's application requirements.
Automated profiling
Analysis modules:
Freely selectable analysis modules
Optimized to customer requirements
Expansion with additional modules possible on site
Spark stand:
Open spark stand for high samples
Throughput and various sample geometries
Minimized argon consumption thanks to argon saving module
Optimized argon flow
Reduced cleaning intervals
Spark stand plate can be easily replaced
Temperature-absorbing design without water cooling
Integrated shutter system for optimum plasma view
Excitation system:
Fully digitized plasma generator with digital discharge definition,
digital pulse generation and digital offline pulse control
32 MHz microcontroller
Max. Spark duration: 4000 µs
Max. Spark power 4 kW
Display system:
Separate microcontroller for each CCD
Serial source interface
Spectrometer:
External, state-of-the-art computer
PC system with Windows operating system
Keyboard and mouse
Monitoring
Software:
Spark Analyzer Pro MAX software for analytical operation and calibration
Continuous automatic hardware diagnostics in the background
Automatic verification and identification of alloy/quality
Results Manager
Online maintenance scheduler
Ambient conditions:
Room temperature: 10-30°C
Conditions: (10-30°C)
Relative humidity:
Listing

7,623 km
Walk-in climate chamber
WeissWK 27'/50-150 -50°C bis 150°C
Call
Condition: excellent (used), White
Type: WK 27'/50-150
Climate cabinet
Water-cooled
Technical data:
Test cabinet designation: WK 27'/50-150
External dimensions
Height 3500 mm, width 3400 mm, depth 6000 mm
Control cabinet dimensions
Height 2000 mm, width 2400 mm, depth 400 mm
Internal dimensions
Height 3000 mm, width 3000 mm, depth 3000 mm
Floor load 30000 N/m³ (surface load)
Test chamber volume: approx. 27000 liters
Test specimen mass 1000 kg
Cold / heat operation
-50°C to 150°C
Heating 1.0 K/min
Cooling 1.0 K/min
Temperature stability +- 0.3 to 1.0 K (time-related)
Temperature stability +- 0.1 to 0.5 K (time-related)
Air conditioning operation
Cgjlijvx Nfbjpf I Hjt
10 – 90°C
Humidity 10...98% r.h.
Temperature stability +- 0.1 to 0.5 K (time-related)
Dew point range +4 to +84 °C
3/N / PE AC 400 V ±10% 50 Hz
Weight: 7000 kg
Refrigerants R23 and R404A
With extra floor plates to increase floor load
The following information is for your safety as a buyer! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

7,623 km
Alternating climate chamber environmental simulation
BinderMK 720 -40°C bis 180°C
Call
Condition: excellent (used), Binder
Type: MK 720
Environmental simulation cabinet for cyclic temperature tests.
The Binder cabinet of the MK series is suitable for all heat and cold tests between -40°C and 180°C.
The natural simulation through the APT.line preheating chamber technology is particularly unique.
It is a clever alternative to complex individual solutions for cyclic temperature tests.
External dimensions: width: 1340 mm, height 2100 mm
Depth plus 50 mm controller and door handle 1230 mm
Distance from wall 160 mm
Viewing window width 370 mm
Viewing window height 770 mm
Cgslijvx Ndwspf I Hot
Number of doors 1
Internal dimensions: width: 1000 mm, height: 1168 mm, depth: 600 mm
Interior volume 720 liters
No. Slots 5
Load per slot 40kg
Permissible total load 120kg
Empty weight 570kg
Temperature range -40°C to 180°C
Electrical data
Nominal voltage 400 V 3 N ~ 50/60 Hz
Nominal power 6.0 kW 14.5 A
Calibration certificate here 12/19/2023
Refrigerant: R404 A
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,623 km
Indentec hardness tester 60 to 150 kgf
Zwick / Roell4150DLC-A
Call
Condition: excellent (used), Zwick / Roell
Zwick Indentec hardness tester
Type: 4150DLC-A
Technical data:
Available test forces 60, 100 and 150 kgf
Power supply 115 / 230 V (50 - 60 Hz) 2/1A 1L/N/Pe
+ EO-4010C camera and ueye software
Condition: used
Cgjlipjvxrxdjf I Hot
Weight approx. 60kg
Scope of delivery: (See image)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Material testing (495)
Search Werktuigen now with more than 200,000 used machines:
Find out now
+49 201 857 86 180
+49 201 857 86 180
Create listing
*per listing / month