Carbon-sulfur analysis
Leco C 230

Fixed price plus VAT
€5,700
Condition
Used
Location
Borken Germany
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
Carbon-sulfur analysis Leco C 230
more Images
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Leco C 230
Show images
Show map

Machine data

Machine type:
Carbon-sulfur analysis
Manufacturer:
Leco
Model:
C 230
Condition:
used

Price & Location

Fixed price plus VAT
€5,700
Location:
Einsteinstraße 8a, 46325 Borken, DE Germany
Call

Details about the offer

Listing ID:
A176-65683
Reference number:
24420
Update:
07.03.2025

Description

Leco
LECO C230 CARBON ANALYZER
Carbon analyzer C230
The LECO C230 carbon analyzer is a microprocessor-based,
software-controlled instrument for measuring the carbon and sulfur
sulfur content in metals, ores, ceramics and other inorganic
inorganic materials. The C230 uses an induction furnace
and measures carbon by infrared absorption.
The infrared (IR) source consists of nichrome wire, which is heated by
heated to 8500 °C by resistance heating. The IR source
emits visible energy and all wavelengths of the infrared spectrum
Carbon dioxide can be used for the description; the same principle applies to sulphur detection.
Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum.
within the IR spectrum. Energy from the IR source is absorbed,
when the gas flows through the cell, preventing it from reaching the IR detector.
An IR cell is used both as a reference and for measurement.
Total carbon in the form of carbon dioxide is detected continuously and simultaneously.
The initial reference level or baseline for the detector is set by passing oxygen through the cell.
established by passing oxygen through the cell to drive out residual atmospheric gases.
Technical data:
Gas required:
Carrier gas: Oxygen 99.5 % pure, 40 psi
Pneumatic gas: Compressed air, nitrogen or argon, 40 psi (2.76 bar),
Source must be free of oil and water Gas flow (based on nominal analysis time)
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulator
Oxygen: 501-291 O 2 pressure regulator
Compressed air: 766-036 Compressed air regulator
Inert gas: 764-216 Inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data transmission: Included
Data storage
Without PC: 10 sample weights, 50 responses, 5 methods
Without PC: Internal membrane /External optional display
Without PC: Liquid crystal (16 x 26 characters)
Dodpfx Aaju Ndyxemewc

Power requirement
Determinator: 230 Ṽ̃̃, ± 10 %, 50/60 Hz,
Single-phase, 15 amps max.
Operating current: 12 A
Standby current: 4 A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.

The listing was translated automatically. Translation errors are possible.

Seller

Last online: Today

Registered since: 2012

599 listings online

Trustseal Icon
Call

Send inquiry

Countryus 
Germany
Austria
Switzerland
United States
United Kingdom
France
Belgium
Spain
Mexico
Italy
Netherlands
Poland
Russian Federation
Belarus
Ukraine
Estonia
Turkey
New Zealand
Ireland
Czech Republic
Denmark
Finland
Sweden
Norway
Luxembourg
Greece
Lithuania
Latvia
Iceland
Portugal
Brazil
Venezuela
Argentina
Hungary
Slovakia
Romania
Moldova
Slovenia
Serbia
Montenegro
Albania
Croatia
Bulgaria
Macedonia
Bosnia and Herzegovina
Israel
Egypt
Morocco
India
Indonesia
South Korea
Japan
Thailand
Malaysia
Vietnam
China
Taiwan
Iran
Bangladesh
Afghanistan
Note: Your inquiry will be forwarded to all sellers in this machine category. This allows you to receive a large number of offers.
The inquiry could not be sent. Please try again later.

Telephone & Fax

+49 2861 ... show