English
German English Dutch Dutch
more images
10
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Remarks A heat exchanger has no type plate. The recoolers have different connections. Bkw2fwgsuk Heat exchanger exchange surface 4.8 m² Type plate Year of construction 1995 Insulation available Jacket volume Jacket volume 210 litres Pipe chamber volume Pipe chamber 60 litres
EMAG MCW-100A-03MZ-3407 EMAG MCW-100A-03MZ-3407 EMAG MCW-100A-03MZ-3407 EMAG MCW-100A-03MZ-3407
more images
4
Call
Leipzig, Germany Germany
(dealership location)
7963 km
used
cooling capacity: 10 kW drive power: kW Fq3v2ur voltage: 400/460 V Number of ventilators: 2 (Ø 260mm) St. operating pressure: 25 bar total power requirement: 3,7 / 4,2 kw weight of the machine ca.: t dimensions L x W x H: m
Deltatherm HKG-W-50/12 - Thermal fluid unit Deltatherm HKG-W-50/12 - Thermal fluid unit Deltatherm HKG-W-50/12 - Thermal fluid unit Deltatherm HKG-W-50/12 - Thermal fluid unit Deltatherm HKG-W-50/12 - Thermal fluid unit
more images
5
Call
Barneveld, Netherlands Netherlands
(dealership location)
7530 km
used
* General * SKU900WP088 * LocationBarneveld * What you can expect from Foeth: all our machines are in working condition, and at a reduced price compared to new. They are ready for shipping to any destination worldwide. You are welcome to inspect our machines in Barneveld, The Netherlands. Visit our website Foeth for more information and many more machines! D8ih9ih
Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw
more images
8
SANYO Water Heat Exchanger Model: SGP-WE170J2 Power source: 220-240 V AC, 1 phase, 50 Hz Maximum electrical power: 9 kW, 0.05 A (continuous operation) Device protection: IP24 Cooling capacity: 50 kW Heating power: 60 kW Heat input (HS) (cooling): 43.5 kW Heat input (HS) (heating): 46 kW Refrigerant: R407C Design pressure high pressure side: 30 bar Design pressure low pressure side: 16 bar If you need more information. We are here to help! Please contact us using the form or give us a call Bfumh...
Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG
more images
6
Call
Riverside Trading Estate, Penketh, Warrington WA5 2UL, UK United Kingdom
6979 km
new
New and Unused Alfa Laval M10-BDFG Heat Exchanger Vow3j7hh Please see photo of information plate for relevant details or contact us for further information
Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5
more images
6
Call
Grenzach-Wyhlen Germany
7941 km
1989
ready for operation (used)
Jäggi R29-W5 stainless steel tube bundle heat exchanger This heat exchanger was expanded by our company and was in working condition before dismantling. Fb9383p Ask for the details. The price is ex works Grenzach. Visit us at permasale(.)de, here you will find our current complete stock programme.
more images
7
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Others Front head from 1.4571 (V4A); smaller dents in the iso-mantle Bkw2jiuwew Heat exchanger exchange surface 10,0 m² last application brewery type plate insulation existing material insulation jacket stainless steel Jacket volume Jacket volume 75 litres Max. perm. operating overpressure Jacket volume 6.0 bar Max. perm. operating temperature Jacket volume 200 °C Pipe chamber volume Pipe chamber 61 litres Max. permissible operating temperature Pipe chamber...
KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK
more images
6
Call
Leipzig, Germany Germany
(dealership location)
7963 km
2003
used
operating pressure: 10 bar Tpsv9tou0 voltage: 400/50 V/Hz control voltage: 24 V total power requirement: 0,76 kw weight of the machine approx.: 160 kg space requirements of the machine approx.: 0,58x0,68x1,35 m heat exchanger application area: transportation of heat energy from a medium to another medium (liquid or gas) connections 3/4" for flow/return 2x both sides 2 Pieces available
Lauda - Thermal fluid unit Lauda - Thermal fluid unit Lauda - Thermal fluid unit Lauda - Thermal fluid unit Lauda - Thermal fluid unit
more images
5
Call
Barneveld, Netherlands Netherlands
(dealership location)
7530 km
used
* General * SKU278N326 * LocationBarneveld * What you can expect from Foeth: all our machines are in working condition, and at a reduced price compared to new. They are ready for shipping to any destination worldwide. You are welcome to inspect our machines in Barneveld, The Netherlands. Visit our website Foeth for more information and many more machines! Zvsj9rqx
APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055
more images
9
Call
Boxmeer Netherlands
7581 km
2004
new
Details Brand APV Model: A 055 Year of manufacture: Unused, 2004 Serial Number: 62988 Dimensions LxWxH (mm) 1000 x 800 x 1700 2tjmi3 Weight (Kg) approx 800 Max. working pressure (Bar) 6 Made in Denmark Comments Heating surface 40,2 m2, Working pressure 6 bar, test pressure 9 bar, volume side1: 65,7 ltrs, volume side 2: 65,7 ltrs, working temerature max. 100 degrees celcius Price on request
QVF HEC600/150
more images
1
Call
Riverside Trading Estate, Penketh, Warrington WA5 2UL, UK United Kingdom
6979 km
excellent (used)
Pre-owned but in excellent condition. This is a QVF HEC600/150 glass coil heat exchanger. We currently have 3 in stock Details: Heat Transfer Area - 15m² Height - 1250mm Diameter - 600mm Blky28eyqc Ports for inlet and outlet are 50mm
SPIRAX SARCO unbekannt
more images
1
Call
Ulm Germany
8024 km
1997
good (used)
Jacket and pipes made of 1.4571 Cjezttqo Power 600 kW 7,400 litres of water from 10 °C to 80 °C at 8 bar saturated steam and 90 °C condensate temperature
more images
6
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Remarks 3 feet made of V2A with plastic rollers; 2 crane eyes heat exchanger type plate year of construction 2002 insulation available Shell space Volume shell space 216 litres Max. permissible operating temperature shell space 80 °C Pipe chamber Volume of pipe chamber 1,000 litres Max. permissible operating temperature of pipe chamber 80 °C 3cj9bjyh Technical data / dimensions Outer diameter 520 mm Overall height 1,950 mm
Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher
more images
10
Tube bundle heat exchanger in U-tube design with 4-way flow. Pressure test was carried out All TÜV protocols/drawings available Material tube/jacket: 1.4541 Tube dimension: 10x1mm Exchanger surface: 18m² Gxr22jej max. overpressure jacket: 10 bar max. overpressure tube: 10 bar max. temperature: 200°C capacity shell side: 50 litres capacity pipe side: 29 litres connection jacket side: 3" max. flow rate jacket: 80m³/h connection pipe side: 1" max. flow rate pipe: 8-10m³ weight: approx. 200kg Overal...
Friga-Bohn unknown Friga-Bohn unknown Friga-Bohn unknown Friga-Bohn unknown Friga-Bohn unknown
more images
5
Call
Barneveld, Netherlands Netherlands
(dealership location)
7530 km
used
* General * SKU254S207 * LocationBarneveld * What you can expect from Foeth: all our machines are in working condition, and at a reduced price compared to new. They are ready for shipping to any destination worldwide. You are welcome to inspect our machines in Barneveld, The Netherlands. Visit our website Foeth for more information and many more machines! B08czwpnrd
more images
3
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Others Front head from 1.4571 (V4A); smaller dents in the iso-mantle Pumo3e Heat exchanger last use brewery nameplate year 1987 Insulation available Material insulation jacket stainless steel Jacket volume Jacket volume 44.8 litres Max. perm. operating overpressure Jacket volume 3.0 bar Max. perm. operating temperature Jacket volume 142 °C Pipe chamber volume Pipe chamber 33.3 litres Max. permissible operating temperature Pipe chamber 142 °C Max. permissibl...
Single Temperiertechnik Oil Advanced D2/D3-350-18-50 - Thermal fluid unit Single Temperiertechnik Oil Advanced D2/D3-350-18-50 - Thermal fluid unit Single Temperiertechnik Oil Advanced D2/D3-350-18-50 - Thermal fluid unit Single Temperiertechnik Oil Advanced D2/D3-350-18-50 - Thermal fluid unit Single Temperiertechnik Oil Advanced D2/D3-350-18-50 - Thermal fluid unit
more images
5
* General * SKU254S208 * LocationBarneveld * What you can expect from Foeth: all our machines are in working condition, and at a reduced price compared to new. They are ready for shipping to any destination worldwide. You are welcome to inspect our machines in Barneveld, The Netherlands. Visit our website Foeth for more information and many more machines! B2akqy8lfy
more images
5
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Remarks Front head from 1.4571 (V4A); smaller dents in the iso-mantle Heat exchanger exchange surface 7.7 m² last use brewery type plate insulation existing insulation material insulation jacket stainless steel Gkwfhdpd8 Jacket volume Jacket volume 55 litres Max. perm. operating overpressure Jacket volume 5.0 bar Max. perm. operating temperature Jacket volume 170 °C Pipe chamber volume Pipe chamber 48 litres Max. permissible operating temperature Pipe chamb...
more images
5
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger last use brewery nameplate year 1987 Insulation available Material insulation jacket stainless steel B3gr9smq Jacket volume Jacket volume 44.8 litres Max. perm. operating overpressure Jacket volume 3.0 bar Max. perm. operating temperature Jacket volume 142 °C Pipe chamber volume Pipe chamber 33.3 litres Max. permissible operating temperature Pipe chamber 142 °C Max. permissible operating overpressure Pipe chamber 3.0 bar
more images
4
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger exchange surface 8.5 m² last use brewery type plate year 1984 insulation existing material insulation jacket stainless steel Jacket volume Jacket volume 54 litres Max. perm. operating overpressure Jacket volume 15.0 bar Max. perm. operating temperature Jacket volume 170 °C Bkw2imbfit Pipe chamber volume Pipe chamber 22 litres Max. permissible operating temperature Pipe chamber 170 °C Max. permissible operating overpressure Pipe chamber 4.0 ba...
more images
3
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Remarks Front head from 1.4571 (V4A); smaller dents in the iso-mantle Heat exchanger exchange surface 4.7 m² last use brewery type plate insulation existing insulation material insulation jacket stainless steel insulation material mineral wool Bkw2damaab Jacket volume Jacket volume 34 litres Max. permissible operating overpressure Jacket volume 5.0 bar Max. permissible operating temperature Jacket volume 170 °C Pipe chamber volume Pipe chamber 30 litres Max...
more images
4
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger of last use Gasket manufacture Type plate Jacket volume Jacket volume 83 litres Jacket material AISI304 (V2A) 1.4301 Max. permissible operating overpressure Jacket volume 3.9 bar Max. permissible operating temperature Jacket volume 35 °C Odhpz Pipe chamber volume Pipe chamber 140 litres Material pipes AISI304 (V2A) 1.4301 Max. permissible operating temperature Pipe chamber 150 °C Max. permissible operating pressure Pipe chamber 3.9 bar Techni...
more images
8
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous formerly melting condenser; Outer chamber I: capacity: 420 litres, permissible operating overpressure: -1/+6 bar; permissible operating temperature: 200° C; Outer chamber II: capacity: 66 litres, permissible operating overpressure: -1/+3.2 bar (was reduced from 6 to 3.2 bar by the previous operator); permissible operating temperature: 200° C Heat exchanger Technical documentation Drawing,TÜV papers Exchange surface 21.0 m² Last use Chemistry N...
more images
5
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Other inside:Pressure: 23 barTemperature: 150°CContent: 8,3 Literoutside:Pressure: 12 barTemperature: 190°CContent: 18.5 Liter Remarks Dents in Isomantel Bwxx0ypcaf Heat exchanger last use Dairy prehead 2 preheads missing Year of construction 2012 Insulation available Material insulation jacket stainless steel Shell chamber material shell AISI316 (V4A) 1.4404
more images
6
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Other 8 minutes hot holdingPipes DN 80Length: 647 metersManufacturer: Tetra PakWeight approx. 7 t Remarks 6 height-adjustable feet; minor dents in the insulating jacket; insulating jacket is no longer present in 2 sections (see photos) Heat exchanger last use dairy insulation available material insulation jacket stainless steel Tube chamber material tubes AISI304 (V2A) 1.4301 Technical data / dimensions Total height 3,200 mm Total width 1,550 mm Total lengt...
more images
2
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General condition used Heat exchanger last application Pharmacy Name plate Material insulating jacket Stainless steel Lzeixmr Jacket volume Jacket volume 4 litres Jacket material AISI316 (V4A) 1.4571 Max. permissible operating temperature Jacket volume 100 °C Pipe chamber volume Pipe chamber 3 litres Material pipes AISI316 (V4A) 1.4435 Max. permissible operating temperature Pipe chamber 100 °C Max. permissible operating pressure Pipe chamber 11.0 bar Technical data / dimensions Total length 2,65...
more images
4
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Crp0lmz Heat exchanger of last use Food colouring Nameplate Jacket volume Jacket volume 289 litres Jacket material AISI304 (V2A) 1.4301 Max. permissible operating overpressure Jacket volume 6.0 bar Max. permissible operating temperature Jacket volume 20 °C Pipe chamber volume Pipe chamber 60 litres Material pipes AISI304 (V2A) 1.4301 Max. permissible operating temperature Pipe chamber 150 °C Technical data / dimensions Inner diameter 500 mm Total length 2,6...
more images
6
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Adhesions inside the steam pipe Bi8bleghqw Heat exchanger Technical documents Drawing,TÜV papers Last use Chemistry Type plate Year of construction 2006 Shell space Volume shell space 165 litres Material shell AISI304 (V2A) 1.4541 Max. permissible operating overpressure shell space 13,0 bar Max. permissible operating temperature shell space 300 °C Pipe space Volume of pipe space 350 litres Material of pipes AISI316 (V4A) 1.4571 Number of pipes...
more images
15
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition unused Heat exchanger Technical documents Drawing Exchange surface 4,0 m² Last use Pharmacy Type plate Year of construction 2002 Insulation available Material insulation jacket Stainless steel Shell space Volume shell space 9 litres Material shell AISI316 (V4A) 1.4571 Max. permissible operating overpressure shell space 10,0 bar Max. permissible operating underpressure shell space 1,0 bar Max. permissible operating temperature shell space 50 °C Pipe chamber Volum...
more images
5
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Remarks Room 1: Capacity: 15 liters; max. operating pressure: -1 bar; max. operating temperature: 150°C; Room 2: Capacity: 4 liters; max. operating pressure: 5 bar; max. operating temperature: 50°C; front heads made of Fe, pipes made of stainless steel L20dka0 Heat exchanger of last use Food colouring Nameplate Jacket chamber Material jacket AISI316 (V4A) 1.4571 Technical data / dimensions Diameter inside 140 mm Total length 1,500 mm
more images
9
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Remarks Shell made of heat-resistant structural steel: permissible operating overpressure: 72 bar; permissible operating temperature: 300° C; capacity: 400 litres; tubes made of titanium II: permissible operating overpressure: 200 bar; permissible operating temperature: 300°C; capacity: 100 litres Heat exchanger Technical documents Drawing,Acceptance certificate last Intended use Chemistry L3dupu2 Technical data / dimensions Total length 8.512 mm
more images
3
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General condition used Remarks 1 x prehead gasket defective Bi8bie0pim heat exchanger technical documents drawing exchange surface 2,0 m² last use pharmacy year of construction 2000 insulation available material insulation jacket stainless steel insulation material mineral wool Shell space Volume shell space 27 litres Material shell AISI316 (V4A) 1.4571 Max. permissible operating overpressure shell space 6,0 bar Max. permissible operating temperature shell space 140 °C Pipe chamber Volume of pip...
more images
3
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General condition used Bi8bh2jjul Heat exchanger exchange surface 1,65 m² last application pharmacy type plate insulation existing material insulation jacket stainless steel Jacket volume Jacket volume 4 litres Jacket material AISI316 (V4A) 1.4571 Max. permissible operating overpressure Jacket volume 10.0 bar Max. permissible operating temperature Pipe chamber volume Pipe chamber 3 litres Material pipes AISI316 (V4A) 1.4571 Number of pipes 22 Max. permissible operating temperature Pipe chamber 1...
more images
5
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Flanges partly made of mild steel Heat exchanger Technical documents Drawing,TÜV papers Exchange area 39,0 m² Last use Reflux cooler in a glue production Type plate Shell space Volume shell space 300 litres Material shell AISI304 (V2A) 1.4301 Max. permissible operating overpressure shell space 6,0 bar Max. permissible operating temperature shell space 80 °C Pipe chamber Volume of pipe chamber 410 litres Material of pipes AISI304 (V2A) 1.4541 N...
more images
3
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General condition used Remarks outside polished; possibly unused Heat exchanger Technical documents Drawing Exchange surface 2,12 m² Last use Distillate cooler (1000 l/h; Pharmacy) Type plate Year of construction 2006 Insulation available Material insulation jacket Stainless steel Er3nbmras Shell space Volume of shell space 27 litres Material of shell AISI316 (V4A) 1.4404 Max. permissible operating overpressure of shell space 8.0 bar Max. permissible operating temperature of shell space 100 °C P...
more images
6
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Manufacturer GEA Location Bremen Condition used Bvqgzvogln
more images
4
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger Technical documents Drawing,TÜV papers Exchange area 8.5 m² Last use chemistry Type plate insulation available Material insulation jacket steel Shell space Volume shell space 97 litres Material shell AISI316 (V4A) 1.4571 Max. permissible operating overpressure shell space 8,0 bar Max. permissible operating underpressure shell space 1,0 bar Max. permissible operating temperature shell space 200 °C Pipe space Volume of pipe space 53 litres Mate...
more images
9
Call
Bremen, Germany Germany
(dealership location)
7667 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Differences in the design of the heat exchangers; flanges partly made of mild steel; isosleeves with minor damage (see photos). O0ejp heat exchanger last use dairy insulation available
 

Used Heat exchangers

Completely search Werktuigen and more than 200,000 used machines now.
FEEDBACK
Successful: Task carried out