Climate chamber with humidity 34 litersWeiss
WKL 34/60 -60°C bis 150°C
Climate chamber with humidity 34 liters
Weiss
WKL 34/60 -60°C bis 150°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A162-11179
- Reference number:
- 24134
- Update:
- 15.11.2024
Description
White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
Ksdpotr Dinofx Af Ssfa
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
Ksdpotr Dinofx Af Ssfa
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
7,623 km
Temperature test chamber
Heraeus VötschHT 7010 -70°C bis +180°C
Heraeus VötschHT 7010 -70°C bis +180°C
Listing
Borken
7,623 km
Small climate chamber 60 liters with humidity
CTSC-40/60 -40 bis +180°C
CTSC-40/60 -40 bis +180°C
Listing
Borken
7,623 km
Corrosion test chamber
VLMSAL 400 V.713.062.000
VLMSAL 400 V.713.062.000
Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
VötschVC³ 4100 990 Liter -42°C bis +180°C
Listing
Borken
7,623 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
Listing
Borken
7,623 km
Salt spray chamber
KöhlerHK500
KöhlerHK500
Listing
Borken
7,623 km
Shaker system with amplifier
LDSV895-440 HBT900C + SPA50K
LDSV895-440 HBT900C + SPA50K
Listing
Borken
7,623 km
Walk-in climate chamber
WeissWK 27'/50-150 -50°C bis 150°C
WeissWK 27'/50-150 -50°C bis 150°C
Listing
Borken
7,621 km
LDS V726 Permanent magnet shaker
LDSLDS PA2000 LDS 726
LDSLDS PA2000 LDS 726
Listing
Borken
7,623 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
VötschVCL 7003 -70°C bis +180°C
Your listing has been deleted successfully
An error has occurred