Temperature cabinet 110 litersVötsch
VT 7011 -70°C bis +180°C
Temperature cabinet 110 liters
Vötsch
VT 7011 -70°C bis +180°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Temperature cabinet 110 liters
- Manufacturer:
- Vötsch
- Model:
- VT 7011 -70°C bis +180°C
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A675-3949
- Reference number:
- 22469
- Update:
- 15.11.2024
Description
Here we offer a Heraeus Vötsch temperature cabinet.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Bsdpehrdy Ssfx Af Soct
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
The listing was translated automatically. Translation errors are possible.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Bsdpehrdy Ssfx Af Soct
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
7,623 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
VötschVT 7011 -70°C bis +180°C
Listing
Borken
7,623 km
Small climate chamber 60 liters with humidity
CTSC-40/60 -40 bis +180°C
CTSC-40/60 -40 bis +180°C
Listing
Gransee
7,899 km
Climatic cabinet -70 to + 180°C
VötschVMT 07/35
VötschVMT 07/35
Listing
Borken
7,623 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
VötschVTS 7034-5 -70°C bis +180°C
Listing
Borken
7,614 km
Climatic cabinet -70 to + 180°C
VötschVMT 07/35
VötschVMT 07/35
Listing
Borken
7,623 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Listing
Contamine-sur-Arve
7,946 km
Oven
VOETSCHVMT 04/140
VOETSCHVMT 04/140
Listing
Borken
7,623 km
Temperature test chamber 280 liters
FeutronTPK 200 Typ: 3416/17 -70°C bis +180°C
FeutronTPK 200 Typ: 3416/17 -70°C bis +180°C