Used material testing for sale (478)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing
Borken
7,623 km
Environment and Stability Chamber
IVA EngineeringHeißluftprüfkammer M5386
Call
Condition: excellent (used), IVA Engineering
Type: M5386
Environment and stability chamber
Dry Hot Air Test Chamber
Cpsdod Nfrlopfx Af Dju
Dry hot air test chamber
Rated voltage: 415V AC/20A
Dimensions:
90.55x78.74x90.55 in - 2204.60 lb
2300x2000x2300 MM - 1000 KGS
Interior Dimensions:
(height x width x depth): approx. 1950 x approx. 1230 x 1510 mm
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Labinot temperature control system
Symax Sytemtechnik SondermaschinenTS 1800
Call
Condition: excellent (used), Here we offer 1800 a Labinot tempering system TS.
Labinot tempering system TS 1800
400V of 3n,50hz, 3 x 35 AT
Weight: approx. 920kg
Type: TS 1800
Condition: pre-owned / used
Scope of delivery: (See image)
(Errors and omissions in the technical data, information are reserved!)
Cpsdpfed Huqhox Af Deu
We can answer questions on the phone for you.
Listing
Borken
7,623 km
Emission test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here we offer a Weiss emission test chamber.
Mini - SHED for Diurnal Loss Measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (Usable 1600) mm.
Housing dimensions: Width 1760 mm x depth 3100 mm x heights 2790 mm
Cedomfny Ispfx Af Depu
Max. floor load 250 kg
Operating range +18 °C ...+45 °C, (at higher temperatures SHED operation is only possible without Tedlar bag)
Temperature range +18 °C ...+45 °C
Temperature constancy ≤ ±1 K (temporal)
Temperature change rate, (heating and cooling) approx. 0.5 K/min., without test material
Duct connection (air inlet and outlet) ∅ 80 mm, in chamber rear wall
Shut-off valve, gas-tight (air inlet and outlet) ∅ 80 mm, gas-tight, pneumatic operation Delivery limit: connection flange of shut-off valve
Cooling water consumption approx. 0.8 m3/h
Voltage: 230/400 V; 3 PH + N + PE; 50 Hz
Rated power: 4,1 kW Rated current: 14,0A
Weight: approx. 2500 kg
type: WT 5,1'/ + 18-45
Condition: used / used
Sale ex location
Scope of supply: (Only the Weiss emission test chamber WT 5,1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.

Get information now
+49 201 857 86 180
+49 201 857 86 180
List now
*per listing / month
Listing
Borken
7,623 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
Cpjdpopz H Hxofx Af Deu
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber 1000 liters
CTSC-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Cpjdpfx Asva Hi Hsf Dju
We will be happy to answer any further questions you may have on the phone.
Discover more used machines
Listing
Borken
7,623 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
Cpodpfx Ajv Ewy Hof Dsu
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Cpedpfxow I Rxrs Af Deu
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
X-ray diffractometer (XRD)
PANalyticalX’Pert PRO MPD
Call
Condition: used, PANalytical
PANalytical X’Pert PRO MPD X-ray Diffractometer (XRD)
Excerpt from the service report:
Device: PANalytical X’Pert PRO MPD
Report date: 07.07.2021
Work performed:
- Reinstallation and commissioning of the system
Csdpfswycatox Af Depu
- Connection of external supply lines
- Warm-up phase
- Complete alignment of goniometer and additional components
- Maintenance carried out, including replacement of defective parts
Spare parts used:
L 3.6V NC/U3 R15.0X52.0 BATTERY. NI-CD
FAN FOR X-CELERATOR UNIT
FILTER, WATER
Motor PW3050
("Device was not tested in-house")
The X’Pert PRO MPD is a highly versatile and powerful X-ray diffractometer (XRD) designed for structural characterization of crystalline materials. It is ideal for pure research as well as routine applications in industry and academia. Thanks to its modular design, fast detection, and control of temperature and atmosphere, it is excellently suited for both routine analyses and complex in-situ experiments.
Key features:
- Multiple measurement geometries possible:
- Reflection measurements in Bragg-Brentano (θ–2θ) mode
- Transmission geometry for powders in capillaries
- Optional SAXS (Small-Angle X-ray Scattering) for nanostructure analysis
- Radiation source and detectors:
- Typically copper anode (Cu-Kα, λ ≈ 1.54 Å)
- X’Celerator detector (1D, ultra-fast) for parallel data acquisition
- Modular system with PreFIX technology:
- Rapid change of optics and sample stages without recalibration
- In-situ measurements at high temperatures:
- Measurements up to approx. 1200°C possible
- Controlled atmosphere: air, nitrogen, oxygen (limited for reducing atmospheres)
Typical applications:
- Phase analysis and quantitative Rietveld refinement
- Determination of crystallite size, microstrain, residual stress
- In-situ investigation of phase transitions, oxidation, crystallization, etc.
- SAXS measurements for analysis of nanoparticles and pore structures
- Broad range of sample types: powders, thin films, ceramics, pharmaceuticals, catalysts, and more
Technical data (typical)
Property & Specification
Angle range (2θ): approx. 0.5° to 150°
Step size: up to 0.002° or finer
Goniometer: vertical, 0–0, radius approx. 240 mm
Temperature range: room temperature up to approx. 1200°C
Atmosphere: air, N₂, O₂ (limited for reducing atmospheres)
Detectors: X’Celerator (1D), proportional counter
Distribution & application areas:
The X’Pert PRO MPD is in use worldwide at, for example:
- Universities (ETH Zurich, TU Dresden, University of Vienna)
- Research institutes (e.g., Max Planck Institutes, ICN2, IS2M)
- Industry (e.g., materials development, pharmaceuticals, chemistry)
Condition: used
Scope of delivery: (See image)
(Specifications and technical data subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
-65° to 0°C and +50 to 200°C
EspecTSA-303EL-W Temperaturschockkammer
Call
Condition: excellent (used), Espec
Type: Espec Model: TSA-303EL-W
Water-cooled
Cold chamber: -65° to 0°C
Heating chamber: +50 to 200°C
System: Two-zone test by damper switching
Temperature fluctuation ±0.5°C
Hot chamber:
Temperature Heating time: Ambient temp. to +200°C within 15 min.
Cooling chamber:
Cpedpjvgw Uajfx Af Deu
Temperature pull-down time: ambient temp. to -70°C within 40 min.
Temperature recovery: within 10 min.
Internal dimensions (W x H x D mm): 970 x 460 x 670
External dimensions (W x H x D mm): 1870 x 1900 x 1770(1805)
Power supply: 400 V AC 50Hz: 70 A
Refrigerant: R449A 5 kg R23 2.0 kg
Weight: approx. 1450 kg
Year of construction 2018
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature cabinet -72°C to +180°C
WeissTempEvent T/800/70/10 800 Liter
Call
Year of construction: 2022, condition: excellent (used), White
Type: T/800/70/10
Water-cooled
External dimensions (HxWxD): 2085 x 1415 x 2810mm
Test room dimensions (HxWxD): 950 x 1100x 800 mm
Volume: 800 liters
Minimum temperature: -72 °C
Maximum temperature: +180 °C
Temperature change rate, cooling: 12.0 K/min
Temperature change rate, heating: 12.0 K/min
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature homogeneity spatially: ±0.5 to ±2.0 K
Temperature gradient: ≤2.0 K
Heat compensation, at +20 °C: 8000 W
Power connection 3/N/PE AC 400 V ±10% 50 Hz or 3/N/PE AC 440 V ±10% 60 Hz
Rated power: 30 KW
Codpfx Afsvxrwgj Djpu
Rated current: 57 A
Operating hours: approx. 10 (never used)
Condition: used
Weight 1600 kg
Scope of delivery: (See picture)
Sold ex location!
(Changes and errors in the technical data, information are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Walk-in climate simulation cell
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation cell
System structure:
The system consists of the following main components:
Walk-in, insulated cell
Air treatment room
Humidification system
Machine room
Switch cabinet
Technical data:
Performance range for temperature testing:
Temperature range -40...+140°C
Temperature constancy, in the supply air: (time-wise) ≤ ± 0.5°C
without them. Test room load according to (DIN 50011 Τ13) EN 60068
Temperature constancy, in the supply air: (spatial) ≤ ± 1.0°C
without thermal test room load according to (DIN 50011) EN 60068
Heating rate (according to DIN 50011) approx. 2.0 K/min
without thermal test room load (according to DIN 50011)
Csdsvx S Hhopfx Af Depu
EN 60068) or test material in the temperature range of -30°C...+85°C
Cooling rate (according to DIN 50011) approx. 2.0 K/min
without thermal test room load (according to DIN 50011)
EN 60068) or test material in the temperature range of -30°C...+85°C
Performance range for climate test:
Temperature range +10...+90°C
Humidity working range 10...approx. 95% r.H
without thermal test room touch
Dew point temperature range +5...+89°C
without thermal test room touch
Humidity constancy (in the supply air) (time-wise) ≤ ± 2.5% r.H
measured in the supply air
Performance range for climate testing with heat compensation
Temperature range + 15...+ 80°C
Humidity 15...approx. 80% r.H
without thermal test room load
with max. 16 kW heat compensation
Dew point temperature range +10...+74°C
without thermal test room touch
Dimensions: test room (WxDxH) approx. 2260 x 4648 x 2260 mm
Dimensions: external dimensions (WxDxH) approx. 2660 x 6460 x 2800 mm
clear doorway test room door (W x H) 2260 x 2260 mm
climate module KB 127 (W x D x H) 1700 x 800 x 1400 mm
switch cabinet (W x D x H) 800 x 500 x 2000 mm
design:
air flow: supply air: perforated sheet on the rear wall, in the ceiling area
exhaust air: perforated sheet on the rear wall, in the floor area
temperature control:
direct cooling by evaporation of
refrigerant in a finned heat exchanger:
heating with electric resistance heater
dehumidification:
direct dehumidification by evaporation of
refrigerant in a heat exchanger
interior paneling: stainless steel
outer paneling: sheet steel, galvanized, plastic-coated
floor design: stainless steel,
floor load 15000 N/m²
wheel load (contact surface ≥4cm²) 1500 N/wheelDoor: double-leaf door, stainless steel, painted on the outside with
viewing window (WxH) l000xl000 mm
Test room lighting: 4 spotlights of 500 W each
Insulation Two-layer insulation, 80 mm PUR foam,
120 mm mineral wool
Refrigerator (1 piece) Bltzer 6G-30.2Y
Refrigerant, R449A!
Refrigeration machine oil SEZ 32
Steam humidifier (1 piece) EDB 40Color:
Cell RAL9010, white
Door RAL9010, white
Machine unit RAL 7032, pebble gray
Control cabinet RAL 7032, pebble gray
Mass:
Total system
approx. 4900 kg
Machine set KB 127 approx. 750 kg
Control cabinet approx. 120 kg
Humidification system approx. 64 kgConnections:
Nominal voltage 400 V +6%/-10% 3/PA 50Hz
Nominal power 95 kW
Nominal current 150 A
Listing
Borken
7,623 km
Temperature cabinet 2240 liters
MytronT2240 –40°C bis +100°C
Call
Condition: used, mytron
Type: T2240
Temperature cabinet, water-cooled
Technical data:
External dimensions: width 1435 mm, height 1955 mm, depth 2590 mm
Dimensions of the test chamber: width 1050 mm, height 1400 mm, depth 1600 mm
Volume of the test chamber: approx. 2240 l
Opening for cables:
2 x 100 mm right
2 x 100 mm left
Temperature range: – 40 °C to + 100 °C at 23 °C room temperature
Temperature stability over time: +/- 0.5 °K
Temperature stability over space: +/- 1.0 °K
Cooling: water cooling,
Inlet and outlet 1" internal thread
Cooling water shut off by solenoid valve when device is OFF
Fault display in the event of a refrigeration machine error
Cooling water consumption: Inlet temperature approx. 15 °C, approx. 15 l/min,
Drain temperature approx. 22 °C (with continuous cooling approx. 27 °C)
Mains connection: 3NPE AC 50 Hz 400 V, 32 A CEE plug
Power consumption: approx. 6.5 kVA
Fuse protection: 3 x 20.0 AT, 3 x 10.0 AT
Cpjdpfevtl Hqex Af Dou
Lighting: 25 watts each on the left and right side of the test room
Exhaust air connection: DN 100 mm plug-in system
Safety device: electronic overtemperature protection, permanently set
Flue gas monitoring with horn
Viewing window: five-pane glazing 130 x 360 mm
Refrigerant: R 404 A approx. 10 kg
Weight: approx. 850 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Cpjdpfxsxb Dm Ie Af Dju
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
7,623 km
Vibration test system
RMSSW 6507 mit TGD 9000-000.00
Call
Condition: used, Technical specifications (manufacturer/model type – without guarantee):
Peak force: “according to manufacturer specifications” approx. ≈ 10 kN
Max. acceleration: “up to approx. 1,000 m/s²”
Max. speed: “typically in the range of approx. 1 m/s to a few m/s”
Components:
- Control cabinet TGA 022/3
- Vibration exciter SW 6507
- Power amplifier TG D 9000-000.00
- Blower
Cpedpfx Afsxtdl Is Dju
Condition: used
Scope of delivery: Vibration test system as shown
(Subject to change and error in technical data!)
For further questions, we are happy to answer your call.
Listing
Borken
7,623 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Codsw S E N Tspfx Af Dspu
Temperature gradient K 3
Change rate
Heating K/min 2.0
Cooling K/min 1.4
Heat compensation max. W 650
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Sound pressure level db(A)
Listing
Borken
7,623 km
Corrosion testing device salt spray chamber
Gebr. LiebischS 1000 A-TR / 42016211
Call
Condition: excellent (used), Liebisch
Type: S 1000 A-TR / 42016211
Chest-mounted units with a 1000-liter test chamber volume for salt spray testing.
Constamatic® TR
This series includes automatically controlled chest-mounted units of type A-TR.
The internal controls are operated via a touchscreen.
All functions are displayed on a touchscreen with intuitive user guidance.
Technical specifications:
Device type: S 1000 A-TR
External housing dimensions: (W x D x H in mm) 2600 x 1120 x 1210
Internal test chamber dimensions: (W x D x H in mm) 1535/1425 x 800/780 x 660/650
Max. sample holder load: 10 kg / level 10 kg
Operating voltage: 230 V +6/-10%
Power consumption S: 2700 W
Humidity control range. S: up to / 70°C
Test chamber control range K: up to / 50°C
Test chamber control range S: up to / 50°C
Frequency: 50/60 Hz
Device fuse: 12 A
Temperature control: PLC
Overtemperature protection: yes
Cedpfx Ajwf Dh Nsf Dspu
Test chamber volume: 1000 liters
Test solution storage capacity: approx. / 150 liters
Test solution consumption per hour: approx. / 0.7 - 1.0 liters
Water filling of base pan KON: 15 liters
Weight: 450 kg
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Resonance testing machine
SincoTecPOWER SWING 20 kN Mot Big Table
Call
Condition: used, Type: POWER SWING 20 kN
Cpsdpfxexrffae Af Dou
Sincotec Resonance Testing System Power Swing 20 kN
Manufacturer Service Performed
General Information:
For sale is a used resonance testing system Power Swing 20 kN from Sincotec Test Systems GmbH. The test bench was operated in single-shift use, with all maintenance carried out regularly by the manufacturer.
Key Features:
- Robust design for continuous operation
- Precise resonance testing up to 20 kN
- Manufacturer maintenance included
- Ideal for research, testing, and development applications
Technical Data – Test Bench
Feature / Value
- Overall height of test bench: 1215 mm (without clamping device)
- Width of test bench: 2005 mm
- Depth of test bench: 1205 mm
- Maximum force amplitude: 10 kN
- Maximum total force: ±20 kN
- Measurement transducer accuracy: min. Class 1 (according to DIN EN 10002-3)
Technical Data – Control Cabinet
Feature / Value
- Overall height of control cabinet: approx. 1800 mm
- Table top height: 1080 mm
- Width of control cabinet: 650 mm (narrow table top) / 1450 mm (wide table top)
- Depth of control cabinet: 700 mm (narrow table top) / 800 mm (wide table top)
- Weight: 152 kg (small table top)
187 kg (large table top); with granite plate: 247 kg
Site Requirements
Feature / Value
- Required space: 4.3 × 3.0 m
- Required ceiling height: 2.5 m
- Floor load capacity: 234 N/cm²
Power Requirements
Feature / Value
- Voltage: 400 V three-phase AC with neutral and protective earth
- Phase rotation: clockwise sequence
- Voltage fluctuation: ≤ ±10 %
- Short voltage dips: < 20 ms
- Limits for continuous interference: interference class A according to VDE 0871
- Frequency: 50 Hz ± 1 %
- Protective earth / ground resistance: < 0.3 Ω
Connection and Fusing
Feature / Value
- Power supply: 400 V / 50 Hz (clockwise phase sequence)
- Connector: CEE plug, 5-pin, 16 A
- Fuse rating: 16 A
Test bench weight: approx. 3.6 t
Max. weight of clamping device: 250 kg
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical specifications!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Codpfxeuxq T De Af Djpu
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature cabinet
VötschVTS 7011-5
Call
Condition: good (used), Vötsch
Type: VTS 7011-5
Heraeus Vötsch temperature chamber, water-cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
External dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ± 0.3 to 1 K
Spatial temperature deviation ± 0.5 to ± 2 K
Temperature change rate cooling 6 K/min
Cjdpfjum Uzmex Af Depu
Temperature change rate heating 10 K/min
Refrigerant: R-404 A / R 23
Voltage 3/N/PE AC 400V±10% 50Hz
Rated power 7.5 kW
Rated current 13 A
Weight: 360 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Cpodpfxsun Rv Ne Af Dju
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climatic chamber
RS-Simulatoren
Call
Condition: excellent (used), RS Simulators
Here we offer a climatic test chamber.
Water cooled
300 liters
Temperature range from -75 °C to +180 °C
Time deviation +- 0.2 K to +- 0.8 K
Average heating rate: approx. 2.1 K/min
Codoiivgvopfx Af Depu
Average cooling rate: approx. 1.2 K/min
Humidity range from 10 % to 98 % rel. humidity
Working climate range
Temperature: 10 °C to 95 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 1000 mm 1800 Height mm 1400 Depth mm
Voltage: 3x400V/N/PE Current: 40A
Refrigerant: R404a / R23
Type: KS 300 / 75
Weight: 630 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See pictures)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Werktuigen

Listing
Borken
7,623 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a temperature test chamber.
Cpodpjiqk Absfx Af Dsu
Weiss temperature test chamber water cooled
Technical data:
Test cabinet designation: WT-600/70
Outer dimensions with hinges and door lock
height 1995 mm, width 1090 mm, depth 1660 mm
Outer dimensions without hinges and door lock
height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions:
Height 950 mm, width 800 mm, depth 800 mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70°C to 180°C
Temperature change per time
cooling approx. 2.5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse on site: 32 A slow blow
Permissible test material weight
Total load of grate supports 80kg
test chamber floor 80kg, insert grate 40kg
Refrigerant: R 404A/R23
Weight: 675kg
Type: WT-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate chamber
CTSC-40/200
Call
Condition: excellent (used), CTS test cabinet climatic chamber
Here we offer a CTS climatic chamber.
Air cooled
Test chamber volume: 200 liters
Test chamber dimensions: Height 750, width 650, depth 400 mm
External dimensions: Height 1800, width 920, depth 1345 mm
Temperature working range
temperature range: -40°C / +180°C
cooling speed: 4 K / min
heating speed: 4 K / min
Max. heat radiation at +20°C: 3500 W
Temperature constancy, temporal: ≤± 0.3 K.
Climate working range
Temperature range: +10°C to +95°C.
Humidity range: +10%to +98% r.H.
Csdpfx Afjhwhzwj Dopu
Connection: 400 V +6% -10%, 3/N, 50 Hz
Rated current 9.4 A
Rated power 4,8 kw
Weight: approx. 450 kg
Refrigerant R404A
Type: CTS C-40/200
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Multifunctional cabinet with humidity
BIAC890TH +15°C bis +30°C
Call
Condition: excellent (used), Here we offer a BIA multifunctional cabinet.
BIA Multifunctional Cabinet
Temperature range +15°C to +30°C and humidity
Refrigerant: R-404A
230V 50Hz 10A
Type: C890TH
For you as a buyer the following information for your safety!
Cedpfx Afjfktnys Dspu
The following points are carried out at our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We can answer further questions for you on the phone.
Listing
Borken
7,623 km
Vibration generator | Power amplifier
RMSSW 1511/2
Call
Condition: good (used), RMS
RMS vibration exciter with power amplifier and cooling fan
Vibration exciter SW 1511/2
Power amplifier TGD 3000-000 00
Csdpfx Afsdhxlgo Dspu
IN: 3X400V-50Hz 14.5 KVA
Cooling fan SWG 108
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used material testing (478)
Search Werktuigen now with more than 200,000 used machines:Browse through the most popular machine descriptions:
- International 1046
- International 1055
- International 1246
- International 1455
- International 3288
- International 353
- International 3688
- International 383
- International 433

Get information now
+49 201 857 86 180
+49 201 857 86 180
List now
*per listing / month




























































































































































































































































