Weiss climate test chamber ClimeEvent C/1000/70/5, -70°C to +180°C, 1000 liters, with humidity contrWeiss
ClimeEvent C/1000/70/5
Weiss climate test chamber ClimeEvent C/1000/70/5, -70°C to +180°C, 1000 liters, with humidity contr
Weiss
ClimeEvent C/1000/70/5
Condition
Used
Location
Borken 

Basic data
- Machine type:
- Weiss climate test chamber ClimeEvent C/1000/70/5, -70°C to +180°C, 1000 liters, with humidity contr
- Manufacturer:
- Weiss
- Model:
- ClimeEvent C/1000/70/5
- Condition:
- used
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A218-44598
- Reference number:
- 25180
- Update:
- 15.10.2026
Description
Weiss
Climate testing chamber ClimeEvent C/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2019,
operating hours 3577.95 h.
For sale is a high-quality climate testing chamber of the type ClimeEvent C/1000/70/5.
The device is used in industry, development, and quality assurance to test components and products under extreme temperature and climatic conditions.
The chamber enables realistic simulations of environmental conditions – from extreme cold to high temperatures and humidity levels.
Ideal for electronics, automotive, material testing, and research.
The device operates reliably and reproducibly and is designed for long-term tests and tests in accordance with standards.
With this climate chamber, temperature and humidity conditions can be specifically set and controlled.
This allows the aging, stress, and function of components to be tested under real environmental conditions.
Typical applications include temperature cycling tests, climate tests with humidity, and endurance tests.
Due to the rapid temperature change (up to approx. 5 K/min), accelerated tests are also possible.
Technical data:
Type: ClimeEvent C/1000/70/5
Gsdpfxsy Iyx Aj Aipeuh
Year of manufacture: 2019
Temperature range: approx. -70 °C to +180 °C
Temperature change rate: up to approx. 5 K/min
Humidity range: approx. 10 % to 98 % RH
Internal dimensions (test chamber): approx. 950 x 1100 x 950 mm
Volume: approx. 1000 liters
External dimensions (approx.): 2000 x 1415 x 2030 mm
Power connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 21 kW
Rated current: approx. 34 A
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Climate testing chamber ClimeEvent C/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2019,
operating hours 3577.95 h.
For sale is a high-quality climate testing chamber of the type ClimeEvent C/1000/70/5.
The device is used in industry, development, and quality assurance to test components and products under extreme temperature and climatic conditions.
The chamber enables realistic simulations of environmental conditions – from extreme cold to high temperatures and humidity levels.
Ideal for electronics, automotive, material testing, and research.
The device operates reliably and reproducibly and is designed for long-term tests and tests in accordance with standards.
With this climate chamber, temperature and humidity conditions can be specifically set and controlled.
This allows the aging, stress, and function of components to be tested under real environmental conditions.
Typical applications include temperature cycling tests, climate tests with humidity, and endurance tests.
Due to the rapid temperature change (up to approx. 5 K/min), accelerated tests are also possible.
Technical data:
Type: ClimeEvent C/1000/70/5
Gsdpfxsy Iyx Aj Aipeuh
Year of manufacture: 2019
Temperature range: approx. -70 °C to +180 °C
Temperature change rate: up to approx. 5 K/min
Humidity range: approx. 10 % to 98 % RH
Internal dimensions (test chamber): approx. 950 x 1100 x 950 mm
Volume: approx. 1000 liters
External dimensions (approx.): 2000 x 1415 x 2030 mm
Power connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 21 kW
Rated current: approx. 34 A
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Weiss SC 1000/+20IU Corrosion Climate Alternating Test Chamber, Salt Spray Test Chamber
WeissSC 1000/+20IU
WeissSC 1000/+20IU
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss Temperature Test Chamber TempEvent T/1000/70/5 -70°C to +180°C 1000 liters
WeissTempEvent T/1000/70/5
WeissTempEvent T/1000/70/5
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
WeissTempEvent T/1000/70e/5
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss Technik temperature test chamber TempEvent T/1000/70e/5 -70°C to +180°C 1000 litres
WeissTempEvent T/1000/70e/5
WeissTempEvent T/1000/70e/5
Your listing has been deleted successfully
An error has occurred