Climate chamberWEISS
WK1-1000/70
Climate chamber
WEISS
WK1-1000/70
Condition
Used
Location
Borken 

Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A221-85452
- Reference number:
- 24046
- Update:
- 23.06.2026
Description
Weiss
Type: WK1-1000/70
Weiss Climate Testing Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Control panel: "Touchpanel"
All control and operating commands can be initiated on the "Touchpanel" by simply touching the function symbols.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthroughs:
1 feedthrough, diameter 125 mm, installed on the right
1 feedthrough, diameter 50 mm, installed on the left
Lajdpjzgbtpefx Am Tsc
Volume: 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, height 1980 mm
Data for temperature tests:
Minimum temperature: -70 °C
Maximum temperature: +180 °C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 2 K
Temperature change rate, heating: 4 K/min
Temperature change rate, cooling: 2.5 K/min
Maximum heat compensation: 2750 W
Data for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 29A, rated power: 19.8 kW
Refrigerant: R-452A / R23
Weight: approx. 910 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
The listing was translated automatically. Translation errors are possible.
Type: WK1-1000/70
Weiss Climate Testing Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Control panel: "Touchpanel"
All control and operating commands can be initiated on the "Touchpanel" by simply touching the function symbols.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthroughs:
1 feedthrough, diameter 125 mm, installed on the right
1 feedthrough, diameter 50 mm, installed on the left
Lajdpjzgbtpefx Am Tsc
Volume: 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, height 1980 mm
Data for temperature tests:
Minimum temperature: -70 °C
Maximum temperature: +180 °C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 2 K
Temperature change rate, heating: 4 K/min
Temperature change rate, cooling: 2.5 K/min
Maximum heat compensation: 2750 W
Data for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 29A, rated power: 19.8 kW
Refrigerant: R-452A / R23
Weight: approx. 910 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred















