Description
Huda Technology HUD-G809 Drop Shock Test System
The system is also suitable for testing batteries.
Max load: 100 kg
Table size: 500 mm x 600 mm
Peak impact acceleration range (half-sine wave): 150 - 6000 m/s²
Pulse duration (half-sine wave): 0.5 - 30 ms
If the pulse duration is less than or equal to 3 ms, the tolerance for peak acceleration is ±20%; the tolerance for pulse duration is ±15%.
If the pulse duration is greater than 3 ms, the tolerance for the waveform should comply with the range specified in the standard.
Hnedpfx Aozikb Ish Esr
Velocity tolerance: ±15%
Hydraulic brake prevents secondary impact.
Overall table dimensions: 1000 x 750 x 2450 mm
Weight: 3600 kg
Power consumption: 5.5 KVA
380V ±10% AC 50 Hz
Condition: used
(We reserve the right to make changes and correct typing errors in technical data and specifications!)
If you have any other questions, we would be happy to answer them by phone.
The listing was translated automatically. Translation errors are possible.
The system is also suitable for testing batteries.
Max load: 100 kg
Table size: 500 mm x 600 mm
Peak impact acceleration range (half-sine wave): 150 - 6000 m/s²
Pulse duration (half-sine wave): 0.5 - 30 ms
If the pulse duration is less than or equal to 3 ms, the tolerance for peak acceleration is ±20%; the tolerance for pulse duration is ±15%.
If the pulse duration is greater than 3 ms, the tolerance for the waveform should comply with the range specified in the standard.
Hnedpfx Aozikb Ish Esr
Velocity tolerance: ±15%
Hydraulic brake prevents secondary impact.
Overall table dimensions: 1000 x 750 x 2450 mm
Weight: 3600 kg
Power consumption: 5.5 KVA
380V ±10% AC 50 Hz
Condition: used
(We reserve the right to make changes and correct typing errors in technical data and specifications!)
If you have any other questions, we would be happy to answer them by phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
7,623 km
Shaker system with amplifier
LDSV895-440 HBT900C + SPA50K
LDSV895-440 HBT900C + SPA50K
Listing
Borken
7,614 km
Climate test chamber Temperature test
Andreas SchmidVKT 3.000 /-40/+130
Andreas SchmidVKT 3.000 /-40/+130
Listing
Borken
7,623 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
Listing
Wiefelstede
7,607 km
Conductivity transmitter
E+Hconducta XR 2 0 - 100 %
E+Hconducta XR 2 0 - 100 %
Listing
Borken
7,623 km
Climatic test chamber 1000 liters
Erichsen KorrosionsprüfanlageCORROCOMPACT 618-1000
Erichsen KorrosionsprüfanlageCORROCOMPACT 618-1000
Your listing has been deleted successfully
An error has occurred