Used Schaffer 450 Ts for sale (90,796)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

7,623 km
Climate chamber
CTS CW-40/16
Call
Condition: excellent (used), CTS climate chamber climate test cell
Here we offer a CTS climate chamber climate test cell.
Available from mid-January 2023!
Water cooled
Height adjustable!
Footprint approx. (W x D x H): 3755x 3470x 2480
Test area approx. (W x D x H): 2500x 2720x 2200
Test space volume: approx. 15m³
Temperature range: -40°C to +140°C
Temperature deviation 1 K temporally
Temperature change speed in the average without heat radiation Measured in the supply air
heating: 2 K/min
Cooling: 1 K/min
from +110°C to -35°C
Climatic tests:
Temperature range: +10 °C to +90 °C
Humidity range . +30 % to +95% r.H.
dew point range : +5°C to 89°C
temperature deviation 0,5 K temporal
Humidity deviation ±1- ±3% r.H. temporal
nominal voltage: 400V 3/N, PE, 50 Hz
rated power: 53,5 KW
Rated current: 92,3 A
Compressor: S6J-16.2
+ chiller
Refrigerant: R404A
Weight 5500 kg
Type: CW-40/16
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Dueb Hasip Dp Ss Ufrot
Further questions we can answer on the phone for you.
Listing

7,859 km
Machining center
MATSUURA MAM72-63V
Call
Condition: excellent (used), Year of construction: 2007, Vertical 5-axis machining center
Matsuura MAM72-63V
Year of manufacture: 2007
FANUC 30iM
New spindle 2023 (documents available)
Special accessories for the machine:
Tool magazine capacity 120 places
Deb Ha Ufjvzzzgsrjut
Pallet changer with 2 pallets
HSC. main spindle 40-20,000 min-1
Spindle holder HSK 63
Direct position measuring system
KNOLL high-performance coolant system
Mentalster REINSHAW OMP 60
Technical data:
X-axis: 760mm
Y-axis: 845mm
Z-axis: 660mm
A -120º ~ +30º
C 360º
Table (pallet) 500 X 500 mm
Listing

7,681 km
Chain excavator
KOMATSU55' Ausleger/Long Reach Boom/Tieflöffel
Call
Condition: used, Year of construction: 2023, New Long Reach Boom (long arm), suitable for KOMATSU PC 200 - 240,-6,-7,-8 and others, length 55 feet = approx. 16.76 m., incl. new bucket with teeth, width approx. 970 mm.
Dueb Ha Usvnnbgsfrst

Find out now
+49 201 857 86 180
+49 201 857 86 180
Create listing
*per listing / month
Listing

7,623 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Dueboigg Hnj Ha Ufrot
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature test chamber
CTST -70/600
Call
Condition: excellent (used), CTS Temperature Test Chamber
Duob Ha Ufoichkvjrst
Here we offer you a CTS temperature test chamber.
Water cooled
CTS temperature test chamber
Technical performance data:
Temperature working range
temperature range -70°C / +180°C
cooling speed 3,0 K/min
Heating speed 3.5 K/min
Temperature constancy, temporal ≤± 0.3 K.
Dimensions:
Test volume: 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
connected load 8,2 kW, 14,2 A
Refrigerant: R404A / R23
Weight: 600 Kg
Type: T-70/600
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature test chamber 350 liters
CTSC-40/350 -40/+180°C
Call
Condition: excellent (used), CTS
Dueb Haog Sr Ego Ufrot
Type: C-40/350
CTS air-cooled temperature test chamber
Test chamber volume 350 liters
Test chamber dimensions: Height 750 mm Width 650 mm Depth 720 mm
External dimensions: Height 1800 mm Width 850 mm Depth 1640 mm
Design: Floor-standing appliance
Temperature working range:
Temperature range -40°C/+180°C
Cooling speed: 4.0 K/min
Heating speed: 3.0 K/min
Electrical connection: 400V +6-10 %, 3/N, 50Hz
Connected load: 5.5 kW
Rated current: 8.3 A
Condenser refrigeration machine: Air-cooled
Refrigerant: R-404A
Weight: 550 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Shock test chamber
VötschVT 7012 S3 -80°C bis +220°C
Call
Condition: excellent (used), Here we offer a Vötsch shock test chamber.
Vötsch shock test chamber VT 7012 S3 water cooled
Test chamber volume 120 liters
Number of chambers: 3
Temperature range hot chamber +50°C to +220°C
Temperature range middle chamber -10°C to +90°C
Temperature range cold chamber -80°C to +70°C
Temperature deviation in time ±0.3 to ±1.0 K
Temperature homogeneity spatially related to the set point ±1.0 to ±2.0 K
Test chamber dimensions Width 470 mm Depth 630 mm Height 400 mm
External dimensions Width 960 mm Depth 2150 mm Height 2130 mm
Rated power 13.5 kW
Rated current 30.5 A
Dsbslgux Re Ha Ufreut
Voltage: 3/N/PE AC 400V ±10% 50Hz
Refrigerant R-404 A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S3
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature cabinet 600 liters
CTS T-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Dsb Ha Uouzv Rgsfreut
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate test cell
CTSCW-50/8 Ex
Call
Condition: used, CTS
Type: CW-50/8 Ex
Water-cooled climatic test cell
Type CW -50/8 Ex
1) C means: Climate
2) W means: Walk in
3) -50 means: lower temperature -50 °C
4) 8 means: 8m³ test chamber volume
5) Ex means: Test chamber in explosion-proof design according to
EC Directive 94/9EG (ATEX 95)
Temperature range: -50°C to +120°C
Humidity range: 10 to 95% RH
Dew point range: +5°C to +89°C
Rated voltage: 400V 3/N 50Hz
Rated power: 31.3 kW
Rated current: 49.3 A
Compressor: 4EC-4.2Y/4CC-6.2Y
Refrigerant: R404A/R23
Technical performance data:
Temperature tests:
Temperature range -50 °C to+120 °C
Temperature deviation ±0.5 to 1 K temporal
±2 K, spatial, with a wall distance of 100 mm
Average rate of temperature change without test material
and without heat radiation Measured in the supply air
Heating: 1 K/min from -40°C to +80°C
Cooling: 1 K/min from +80°C to -40°C
Climate tests:
Temperature range +10 °C to +95 °C
Humidity range 10 % to 95 % rel. humidity without heat radiation
in the dew point range +5 °C to +89 °C
Temperature deviation ± 0.5 K in time
Humidity deviation ±1 - ±3 % RH over time
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without heat compensation and without additional equipment.
Dimensions:
Test volume 8 m³
Test chamber dimensions: Width: approx. 1850 mm Depth: approx. 2200 mm Height: approx. 2000 mm
External dimensions: Width: approx 2200 mm Depth: approx 4200 mm Height: approx 2600 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic, infinitely variable capacity adjustment
by electronic monitoring and control system,
environmentally friendly refrigerant R 404 A/R23
Control system:
Dsb Ha Uot Ifztofrout
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site test material control
Weight: approx. 3000 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Small climate chamber 60 liters with humidity
CTSC-40/60 -40 bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/60
CTS small climate chamber air-cooled
Test volume: 60 liters
Temperature range: -40 °C / +180 °C
Humidity range
Dueb Ha Ufsu Hlb Esrot
10% to 98% relative humidity
+10 °C to +90 °C in the temperature range
+5 °C to +89.5 °C in the dew point range
Dimensions (WxDxH):
Inside: 400 mm x 345 mm x 425 mm
Housing: 560 mm x 845 mm x 1575 mm
Refrigerant: R-404A
Nominal voltage: 230V 1/N 50 Hz
Output: 3.3 kW
Rated current: 13 A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Dsb Haeu U Ixmo Ufrsut
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Temperature test chamber water-cooled
Refrigerant: Converted to R-452A
Control:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoints
Deb Ha Ufjvitmdsrsut
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
6-axis robot
MitsubishiRV-3SDB-S15(DA302005R)
Call
Condition: excellent (used), Mitsubishi Industry 6-Axis Articulated Arm Robot
Here we offer Mitsubishi industrial 6 axis articulated arm robot.
RV-Series Industrial Robots
Compact and powerful flexible automation and high reliability.
The RV-Series offers a highly dynamic 6-axis jointed-arm robot for maximum quality.
Type: RV-3SDB-S15
Number of axes 6
Maximum lifting force 3.5 kg
Reach radius 642 mm
Dob Ha Ufsgkg Dljrjut
Weight 38Kg
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing

7,623 km
Temperature test chamber ex protected
CTS-30°C bis +80°C T-30/950 Ex/I
Call
Year of construction: 2011, Condition: excellent (used), Here we offer you CTS temperature test chamber.
Control-32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of the setpoints
Error messages in plain text
Interface RS 232
Free switching channels for on-site test material control
Temperature tests:
temperature range -30°C to +80°C
temperature deviation ±0,3 K temporally
Temperature change rate
heating 2 K/min
Cooling 1.5 K/min to -10°C
Heat radiation approx. 1000 W at +20°C
approx. 200 W at -25°C
Data for gas supply:
Temperature range: -25°C to +55°C
Temperature deviation: ±0.25 K to the test space
Temperature change rate measured on average at a gas flow of 10 Nm³/h: at least as fast as the test chamber
Duob Ha Ufeihb Amerjt
Data for the gas return:
Temperature range: +18°C to +30°C
Temperature deviation: ±0.25 K to the test chamber
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with the large purge volume N2 until the
oxygen content is less than 3%. After that, the system switches to a base load (approx. 10% of the large flush volume).
is switched over.
The nitrogen flow rate of the base load is measured with a flow meter, displayed and monitored by a limit switch.
and monitored by means of a limit switch.
The O2 monitoring system continuously extracts from the test chamber via a flashback arrestor
gas from the test chamber via a flame arrester and passes it over an O2 sensor that monitors the residual oxygen content of the extracted air.
The gas is then returned to the test chamber via a second flashback arrestor.
test chamber. The exhaust pump is monitored by a volumetric flow meter. Further details can be found
can be found in the Dräger operating instructions in the appendix.
The gas device is currently out of service!
The technical data refer to an ambient temperature of +25 °C,
Nominal voltage 400V , without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 950 liters
Test chamber dimensions height approx. 700 mm / width approx. 900 mm depth approx. 1500 mm
External dimensions height approx. 2400 mm / width approx. 1270 mm depth approx. 3125 mm
Operating data:
Electrical connection 400V+6/-10 %, 3/N,50 Hz
rated power 21,6 kW
rated current: 36,5 A
Protection class IP 54
condensate drain pressureless R 1/2" female thread
Sound pressure level < 62 dB(A)
(according to DIN EN ISO 3744
measured at 1m distance from front)
weight: approx. 1500 kg, control cabinet approx. 300 kg
external refrigeration unit
refrigerant R404A / R23
Type: T-30/950 Ex/I
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
Dob Ha Uerbiyfefrsut
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Duebeqnutme Ha Ufret
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Dob Heru Dzuoa Ufreut
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Emission test chamber 480 liters
VötschVCE 1000/S +20°C bis +130°C
Call
Condition: excellent (used), Here we offer you a Vötsch emission chamber.
Water cooled
Dsb Ha Uei Hbylefrjut
Test chamber volume 1000 liters (usable) (916) liters Adjustment tank 480 liters
Performance for temperature tests:
Temperature range +20°C to +130°C
Temperature deviation temporal K ±0.1 to ±0.3
Temperature deviation spatial K ±0,5
Temperature gradient K 1
Temperature rate of change:
Cooling K/min 0.3
Heating K/min 0,4
Performance for climatic tests:
Carrier gas conditioning with climatic module
according to the evaporation principle
Temperature range +20°C to +130°C
Humidity range 5 to 95%
Dew point range +5°C to +60°C
Humidity deviation in time % ±1 to ±3
Carrier gas exchange rate 0.1 to 1.8 chamber volume per hr.
Capacity range for desorption
Desorption temperature up to max. +240°C, adjustable
Test chamber surface temperature between +220°C and +240°C
Purge rate max. 4 m³/h
Test chamber dimensions: Width 750 mm Depth 1630 mm Height 750 mm
test chamber door 670 x 670 mm
Outer dimensions: Width 1350 mm Height 2950 mm Height 2050 mm
rated current 32 A
nominal power 19,0 kW
Electrical connection 3/N/PE AC 400V ± 10% 50Hz
Weight 1200 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VCE 1000/S
Condition: used / used
Scope of delivery: (See picture)
Sale ex location
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Analytical drift detector
Oxford InstrumentsINCAx-act
Call
Condition: excellent (used), Oxford Instruments
Here we offer you an INCAx-act Analytical Drift Detector.
Microanalysis of elements including boron and above
Operating temperature
Normal mode 10-25 degrees
Operating temperature
Dusb Ha Uohx Nchofrjt
extended mode 10-30 degrees
Storage temperature
-25 to 40 degrees and 8 to 80% humidity non-condensing
Operating humidity
Listing

7,623 km
Climate test chamber 2500 liters
VötschVC 4200/S -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC 4200/S
Climate test chamber 2500 liters water-cooled
Temperature test:
Temperature range -40°C to + 180°C
Temperature deviation in time: ± 0.3 to ± 1.0
Spatial temperature deviation: ± 1.0 to ± 2.0
Temperature gradient 2 to 4
Heating speed: 2.0 K/min
Cooling rate: 3.0 K/min
Climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation over time: ± 0.1 to ± 0.5
Temperature deviation over time: ± 1 to ± 1.5
Temperature gradient 2 to 3
Humidity range: 10% to 98% r.h.
Humidity deviation over time: + 1 to 3 % r.h.
Dew point range +5 to +89°C
Test room dimensions: Width approx. 2000 mm x depth 1150 mm x height 1150 mm
External dimensions: Width approx. 3500 mm x depth 1450 mm x height 2100 mm
Nominal voltage 3/N/PE AC 400 V ±10%50Hz
Rated power 13 kW
Nominal current 21 A
Refrigerant R-452A
Dujb Hsu Au Utea Ufrst
Weight approx. 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Dryer for coating materials
Vötsch LTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Dujb Houn Rrqea Ufrst
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Werktuigen

Listing

7,623 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
Dueb Ha Ufou Nh Rbjrot
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber
Vötsch VT 4021
Call
Condition: used, Heraeus Vötsch
Type: VT 4021
Heraeus Vötsch temperature test chamber air-cooled
Housing dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Interior: Width 560 mm Depth 570 mm Height 630 mm
Temperature range -40°C to + 180°C
Temperature deviation in time ±0.2 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature change rate cooling 3.1 K/min
Temperature change rate heating 2.5 K/min
Nominal voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 1.5 kW Rated current: 7 A
2X side feed-through 90 mm
Refrigerant: R-404A
Weight approx. 325 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Deb Ha Ufsu Hf Hhsrsut
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 210 liters
Vötsch VT 7021 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VT 7021
Air-cooled temperature test chamber
Operating terminal Color touch panel
Microprocessor monitoring and control MINCON/32
independent adjustable temperature limiter tmin / tmax
adjustable software temperature limiter min./max.
RS 232 serial interface
Schuko socket
potential-free contact for test material switch-off
Air-cooled refrigeration unit
1 lockable door, single-handed operation
Calibration of 2 temperature values
Mobile version
1x feed-through, NW 80 mm
2x feed-through, NW 125 mm
Test chamber volume 210 liters
Temperature range -70°C to +180°C
Temperature deviation in time ± 0.2 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 1.5 K
Dueb Hasuuf Rne Ufrjt
Temperature change rate heating 2.5 K/min
Temperature change rate cooling 2.5 K/min
Max. heat compensation 800 W
Test chamber dimensions: Width 560 mm Depth 570 mm Height 630 mm
External dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50Hz
Rated power approx. 1.8 kW Rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
Debovaxq Ne Ha Ufrout
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "schaffer 450 ts"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Schaffer 450 Ts (90,796)
Search Werktuigen now with more than 200,000 used machines:
Find out now
+49 201 857 86 180
+49 201 857 86 180
Create listing
*per listing / month