Wilo DL-E 100/145-11/2-S1 CronoTwin dry-run double pump circulation pumpWilo
DL-E 100/145-11/2-S1
Wilo DL-E 100/145-11/2-S1 CronoTwin dry-run double pump circulation pump
Wilo
DL-E 100/145-11/2-S1
ONO plus VAT
€6,638
Condition
Used
Location
Borken 

Basic data
Price & Location
ONO plus VAT
€6,638
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Call
Details about the offer
- Listing ID:
- A189-20911
- Reference number:
- 33806
- Update:
- 07.10.2026
Description
Wilo DL-E 100/145-11/2-S1 Dry-running twin pump
Dry-running twin pump in an inline design for pipe installation or foundation mounting with an integrated frequency converter for electronic control, including constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic power adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual operating mode
Dksdpowbqrtofx Akcou
Setting of the differential pressure setpoint
Setting of the speed (manual operating mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Fault acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal from the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal from the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access restriction
Twin pump management (twin pump or 2 x single pump)
Main/reserve operation (automatic fault switchover)
Main/reserve operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on and off)
Your advantages
Energy saving through integrated electronic power adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/reserve operation and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: €29,006.25
More new and used items can be found in our shop!
International shipping costs on request!
The listing was translated automatically. Translation errors are possible.
Dry-running twin pump in an inline design for pipe installation or foundation mounting with an integrated frequency converter for electronic control, including constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-running twin pump in an inline design with flange connection and automatic power adjustment.
Application
Pumping of heating water (according to VDI 2035), cold water, and water-glycol mixtures without abrasive substances in heating, cold water, and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Controller operation (n=constant)
Manual operating mode
Dksdpowbqrtofx Akcou
Setting of the differential pressure setpoint
Setting of the speed (manual operating mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Fault acknowledgment
External control functions
Control input "Priority OFF"
Control input "External pump switchover" (only effective in twin pump operation)
Analog input 0-10 V, 0-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 2-10 V, 4-20 mA for controller operation (DDC) and remote setpoint adjustment
Analog input 0-10 V for actual value signal from the pressure sensor
Analog input 2-10 V, 0-20 mA, 4-20 mA for actual value signal from the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operating message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated tripping electronics
Access restriction
Twin pump management (twin pump or 2 x single pump)
Main/reserve operation (automatic fault switchover)
Main/reserve operation, pump switchover after 24 hours
Addition operation
Addition operation (efficiency-optimized peak load switching on and off)
Your advantages
Energy saving through integrated electronic power adjustment
Easy operation thanks to Green Button technology and display
Various operating modes: main/reserve operation and parallel operation
Configurable fault behavior tailored to heating and air conditioning applications
Integrated full motor protection (FMP) with tripping electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power consumption P1 max: 13000 W
Motor rated power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Immunity to interference EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: FMP integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: €29,006.25
More new and used items can be found in our shop!
International shipping costs on request!
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Last online: A week ago
Registered since: 2008
541 listings online
Send inquiry
Telephone & Fax
+49 2862 ... show
Your listing has been deleted successfully
An error has occurred