Used Tabe Agb-40 for sale (58,492)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

7,623 km
Climate test chamber Sunlight simulation
VötschVCL 4200/S -40 bis +150 °C 3300 Liter
Call
Condition: excellent (used), Vötsch
Type: VCL 4200/S
Water-cooled climatic test chamber
Irradiation device with metal halide radiator
Door with window
Internal dimensions : Width 2000 mm Height 1000 mm Depth 1150 mm
External dimensions : Width 3300 mm Height 2000 mm Depth 1250 mm
2X pipe penetration 125 mm
Performance range for temperature tests without irradiation
Temperature range - 40°C to +150°C
Temperature deviation ± 0.5 K in time, in the supply air to the test room
Temperature change rate according to DIN 50 011 Part 12
Heating: approx. 1.0 K/min.
Cooling: approx. 1.0 K/min to -30°C
Performance range for climatic tests without irradiation
Temperature range +10°C to +95°C
Temperature constancy ± 1.0 K over time, in the supply air to the test room
Humidity range 10 to 95 % r.h.
Humidity constancy ± 1 to ± 3 % r.h. over time, in the supply air to the test room
Dew point range +5°C to +88°C
Irradiation (solar simulation attachment)
Irradiation type:
4 pcs. 2 kW metal halide radiators each
Irradiance 1000 W/m² ± 5 %
in the range 280 to 3000 nm
Irradiation uniformity ± 50 W in the guaranteed area
Reference plane taking into account the installed
lateral reflector plates
Test area (W x D) 1700 x 800 mm
with distance reference plane - UK irradiation unit
of approx. 750 mm or 400 mm above the floor
Performance range for temperature tests with irradiation
Temperature range -10°C to +100°C
Temperature deviation in time ± 1.0 K, in the supply air to the test room
Rate of temperature change
according to DIN 50 011, part 12
Heating: approx. 1.5 K/min.
Cooling: approx. 0.5 K/min.
Cgohx Djvccwlenk Tjt
Performance range for climatic tests with irradiation
Temperature range + 10°C to + 80°C
Temperature deviation ± 1.0 K over time, in the supply air to the test room
Humidity range 10 % to 85 % r.h.
Humidity deviation ± 1 % to ± 3 % r.h. temporally, in the supply air to the test room
Dew point range + 5°C to + 76°C
Average temperature and humidity changes
If temperature and humidity change simultaneously, the humidity is undefined
Temperature change
+ 90°C to 0°C in 1 h
0 °C to - 40°C in 1 h
0 °C to + 90°C in 1 h
Humidity change
0 °C to + 90°C / 80 % r.h. in 1 h
+ 90°C / 80 % r.h. to 0°C in 1 h,
whereby the final dehumidification value is not defined.
Average temperature and humidity changes
If temperature and humidity change simultaneously, the humidity is undefined
Temperature change
+ 47°C to -30°C in 1 h
- 30°C to + 23°C in 1 h
+ 23°C to + 47°C in 1 h
Connections:
Nominal voltage 400 V +6/-10 %, 3/N, 50 Hz
Rated power 23 kW
Nominal current 49 A
Cekon 63 A plug
Connection cable approx. 3.5 m
Fuse protection 63 A, slow-blow on site
Installation room
Heated, with level floor
Heat output to the installation room approx. 7 kW
with radiation module switched on
Weight approx. 2000 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Listing

7,607 km
Gear motor 1.1 kW 40 rpm
VEMZG3KMR80K4
Call
Condition: good (used), gear motor, electric motor, electric gear motor
-Engine manufacturer: VEM
-Manufacturer gearbox: VEM
-Speed: 40 rpm
-Power: 1.1 kW
Cgjhx Dnkeckbgas Tot
-Design: B3
-Shaft diameter: 40 mm
-Protection class: IP 44
-Quantity: 1 piece available
-Dimensions: 580/250/H300 mm
-Weight: 41 kg
Listing

7,681 km
Motor coach
BOVAFHD 10-340, Euro 3, 40 Sitze, Schaltung
Call
Condition: used, mileage: 627,191 km, power: 250 kW (339.91 HP), first registration: 01/2005, fuel type: diesel, number of seats: 40, gearing type: mechanical, next inspection (TÜV): 05/2025, emission class: euro3, color: white, brakes: retarder, Equipment: ABS, air conditioning, onboard kitchen, parking heater, sideways adjustable, jet ventilation, reading lights, service call, footrests, folding tables, luggage nets, roof luggage rack, double glazing, curtains, front air door, rear air door, seat belts, 2x roof hatch, luggage compartment, electrically adjustable exterior mirrors, vehicle can be fitted with advertising and/or lettering
Cohxovnqpgj Dnk Tsgt
Our offer is generally without new TÜV approval. If a new TÜV inspection is required, we will be happy to make you an offer from our partner workshops! Vehicle can be covered with advertising and/or lettering. Our general terms of delivery and payment apply.
We would be pleased to make you a financing or leasing offer for this object.
Please contact us!

Find out now
+49 201 857 86 180
+49 201 857 86 180
Create listing
*per listing / month
Listing

7,623 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Cshx Dnoup T Uqok Tjgt
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,607 km
Air filter ventilation filter
UCC Parker40 5 Ø 77 x 65 mm
Call
Condition: excellent (used), Compressed air filter, fine filter, filter, pre-filter, intake air filter, air filter housing, air filter housing, generator air filter, ventilation filter
-Manufacturer: UCC, Air Filter Air Breather Filter
Cjhxovyqvqe Dnk Tjgt
-Type: 40 5
-Number: 4x air filters available
-Price: per piece
-Dimensions: Ø 77 x 65 mm
-Weight: 0.2 kg/piece
Discover more used machines
Listing

7,623 km
Climate cell
WEISS WK 50 /40-120
Call
Condition: good (used), White
Type: Walk-in climate simulation cell WK 50 / 40-120
Technical data climatic chamber:
Temperature range -40...+120 °C
Temperature tolerance: +/- 0.5°C
Temperature change rate: 1 K/min
Humidity range
15...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test room volume: 50m³
External dimensions (WxDxH) approx. 4800mm X 6100mm X 2640mm
Test chamber (WxDxH) approx. 4500mm Χ 5000mm Χ 2200mm
Door opening (WxH) approx. 3000mm X 2200mm
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Cgjhsuvi R Aex Dnk Tjt
Listing

7,623 km
Temperature test chamber 190 liters
VötschVT 4018 -40°C bis +180°C
Call
Condition: excellent (used), Here we offer you a Vötsch temperature test chamber.
Air-cooled
Test chamber:
The test chamber is made of highly polished stainless steel material no. 1.4301.
The test specimens can be placed on the supplied shelf or on the test chamber floor.
Test chamber door:
The test chamber door locks the test chamber with a lockable latch.
Touch panel:
All control and operating commands can be triggered on the "touch panel" operating unit by simply touching the function icons.
Feed-throughs:
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs 130∅
Feed-throughs 60 ∅
Test chamber capacity 190 liters
Characteristic values for temperature tests:
Temperature range - 40°C to +180°C
Temperature deviation
temporal ± 0.1 to ± 0.5
Spatial ± 0.5 to ± 2.0
Temperature change rate
Heating 4 K/min
Cooling 3 K/min
Heat compensation max.1000 Watt
Test chamber dimensions: Width 580 mm ,Depth 450 mm ,Height 750 mm
External dimensions: Width 870 mm ,Depth 1280 mm ,Height 1575 mm
Electrical connection:
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Connection cable: 3.5 m
Cohx Dnksqa Dcpj Togt
Fuse protection: 16A slow-blow, on site
Refrigerant: R-404A
Test chamber capacity: approx. 190 liters
Weight: approx. 420 kg
Type: VT 4018
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control unit Water-cooled
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Cgehx Dnsrak Rmjk Tst
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
(refrigerant converted to R-452A)
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Cjhx Derak S Djnk Togt
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber
CTS T-40/600
Call
Condition: excellent (used), CTS Temperature Test Chamber
Here we offer you a CTS temperature test chamber.
Cehx Dnkehxyg Hs Tjgt
Water cooled
Type series: T-40/600
Including metal struts to increase the floor load capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
Outer dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth, approx. 1850 mm
Temperature working range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K temporally
heating speed: 2,5 K/min
cooling rate: 3 K/min
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
rated power: approx. 5,5kW
rated current: approx. 8,5 A
Refrigerant: R404A
Weight: 550 Kg
Type: T-40/600 /011232
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Table autoclave
MelagVacuklav 40-B
Call
Condition: excellent (used), Melag
Here we offer you a tabletop autoclave.
External dimensions: W 320 mm x H 350 mm x D 150 mm
Tank capacity: 18.4 liters
Permissible operating temperature: 144 °C
Permissible operating overpressure: -0.95 - 3 bar
Charging medium: steam/water
Power consumption: 3400 W
Rated voltage: 230 V
Cshxeidmi Ao Dnk Tsgt
Type: Vakuklav 40-B
Scope of delivery: (as shown)
Condition: used / used
The autoclave was in operation until disassembly.
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

7,623 km
Climate test chamber with humidity 1100 liters
EspecARL-1100 -40°C bis 180°C
Call
Condition: excellent (used), Espec
Type: ARL-1100
Air-cooled climatic test chamber
Temperature range: -40 °C to +180 °C
Heating rate of change: up to 4.7 K/ min.
Cooling rate of change: up to 4.4 K/ min.
Humidity range: 10 to 98% r. h.
Internal dimensions: Width 1100 mm Height 1000 mm Depth 1000 mm
External dimensions: Width 1300 mm Height 1955 mm Depth 2005 mm
approx. 1100 liters
Rated current: AC 400 V 3φ,
50Hz 23 A
Weight approx. 600 kg
Refrigerant: R404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
Cshx Dnkst Sug Ho Togt
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate chamber
CTSC-40/200
Call
Condition: excellent (used), CTS test cabinet climatic chamber
Here we offer a CTS climatic chamber.
Air cooled
Test chamber volume: 200 liters
Test chamber dimensions: Height 750, width 650, depth 400 mm
External dimensions: Height 1800, width 920, depth 1345 mm
Temperature working range
temperature range: -40°C / +180°C
cooling speed: 4 K / min
heating speed: 4 K / min
Max. heat radiation at +20°C: 3500 W
Temperature constancy, temporal: ≤± 0.3 K.
Climate working range
Temperature range: +10°C to +95°C.
Humidity range: +10%to +98% r.H.
Connection: 400 V +6% -10%, 3/N, 50 Hz
Rated current 9.4 A
Rated power 4,8 kw
Weight: approx. 450 kg
Refrigerant R404A
Type: CTS C-40/200
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Cgehx Dshwhzwonk Tot
Further questions we can answer on the phone for you.
Listing

7,623 km
Burst test bench
Lindner AGB Berstprüfstand TMM4
Call
Condition: excellent (used), Lindner Bursting Test Stand
Here we offer a Lindner burst test stand.
AGB Bursting Test Stand TMM4
Technical data:
AGB Bursting Test Stand TMM4
Year of manufacture 2015
Rated voltage: 3/N/PE AC 400V
Rated power: 5,5 kW
Temperature range chamber: RT ... 180°C
Temperature range medium: RT ... 135°C
Pressure range: 0 ... 5 bar
Compressed air supply: 6-8 bar
Test medium: glycol / water
Heat transfer oil Fragoltherm Q-HTF
Dimensions: length 2150 mm x width 1050 mm x 2160 mm
Operating voltage: 3/N/PE AC 400V +/-10% 50Hz
Cehslx A T Dex Dnk Tjgt
power: 5,5kW
rated current: 8A
Back-up fuse: 16A
Control voltage: 24VDC
PLC system: S7-1215 DC/DC/RLY
For the commissioning of the burst test bench the following items are necessary:
Pump, cooling tower & fire alarm panel these are not supplied.
Type: AGB burst test rig TMM4
weight approx. 705 kg
Condition: used / used
Scope of supply: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Small climate chamber 60 liters with humidity
CTSC-40/60 -40 bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/60
CTS small climate chamber air-cooled
Test volume: 60 liters
Cjhxju Hlb Es Dnk Tsgt
Temperature range: -40 °C / +180 °C
Humidity range
10% to 98% relative humidity
+10 °C to +90 °C in the temperature range
+5 °C to +89.5 °C in the dew point range
Dimensions (WxDxH):
Inside: 400 mm x 345 mm x 425 mm
Housing: 560 mm x 845 mm x 1575 mm
Refrigerant: R-404A
Nominal voltage: 230V 1/N 50 Hz
Output: 3.3 kW
Rated current: 13 A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate chamber
DycometalCCK -40/1500 T 1500 Liter
Call
Year of construction: 2022, Condition: excellent (used), Dycometal
Type: CCK -40/1500T
Climate chamber water-cooled
Volume liters 1500
Internal dimensions height 1000 mm width 1000 mmm depth 1500 mm
External dimensions Height 2200 mm Width 1293 mmm Depth 3400 mm
Thermal test
Minimum temperature -40°C
Maximum temperature +150°C
Thermal gradient cooling 2.0 K/min.
Thermal gradient during heating 3.5 K/min.
Temperature stability ±0.1°C to ±0.3°C
Temperature uniformity ±0.5°C to 1.5°C
Climate test Temperature range +10°C to +90°C
Humidity range 10% to 98% %RH
Dew point range +6.5°C to +86°C
Humidity stability ±1%RH to ±3%RH
Water-cooled condenser
Nominal voltage 400 V 3N~PE 50 Hz
Cgjhx Deu N Uugenk Tjt
Output 16.1 kW 27.5 A
Refrigerant R-452A
Weight: 1120 kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature test chamber 350 liters
CTSC-40/350 -40/+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350
CTS air-cooled temperature test chamber
Test chamber volume 350 liters
Test chamber dimensions: Height 750 mm Width 650 mm Depth 720 mm
External dimensions: Height 1800 mm Width 850 mm Depth 1640 mm
Cgohx Djg Sr Egonk Tet
Design: Floor-standing appliance
Temperature working range:
Temperature range -40°C/+180°C
Cooling speed: 4.0 K/min
Heating speed: 3.0 K/min
Electrical connection: 400V +6-10 %, 3/N, 50Hz
Connected load: 5.5 kW
Rated current: 8.3 A
Condenser refrigeration machine: Air-cooled
Refrigerant: R-404A
Weight: 550 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate chamber
CTS CW-40/16
Call
Condition: excellent (used), CTS climate chamber climate test cell
Here we offer a CTS climate chamber climate test cell.
Available from mid-January 2023!
Water cooled
Cshxjip Dp So Dnk Tegt
Height adjustable!
Footprint approx. (W x D x H): 3755x 3470x 2480
Test area approx. (W x D x H): 2500x 2720x 2200
Test space volume: approx. 15m³
Temperature range: -40°C to +140°C
Temperature deviation 1 K temporally
Temperature change speed in the average without heat radiation Measured in the supply air
heating: 2 K/min
Cooling: 1 K/min
from +110°C to -35°C
Climatic tests:
Temperature range: +10 °C to +90 °C
Humidity range . +30 % to +95% r.H.
dew point range : +5°C to 89°C
temperature deviation 0,5 K temporal
Humidity deviation ±1- ±3% r.H. temporal
nominal voltage: 400V 3/N, PE, 50 Hz
rated power: 53,5 KW
Rated current: 92,3 A
Compressor: S6J-16.2
+ chiller
Refrigerant: R404A
Weight 5500 kg
Type: CW-40/16
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

7,623 km
Climate test chamber with humidity 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Weiss climate test chamber water-cooled
(refrigerant converted to R-452A)
Temperature test
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ±1.5 K
Climate test:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ±1 K
Humidity deviation, temporal ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Cohx Doq U Sdcsnk Tsgt
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Vacuum pump
Leybold Trivac D 40 B
Call
Condition: excellent (used), Leybold two-stage rotary vane vacuum pump
Here we offer a Leybold two-stage rotary vane vacuum pump.
Cgehx Dnjq Su D Njk Tjt
The TRIVAC B are oil-sealed vacuum pumps based on the rotary vane principle.
The oil injected into the pumping chamber is used for sealing, lubrication and cooling.
The pump body is made up of individual parts without sealing elements.
These are pinned to ensure easy disassembly and reassembly.
Ultimate pressure: 2 x 10-³ mbar
Motor: 3-ph, 230/400 V, 50/60 Hz
Pumping speed (50 Hz): 40 m³/h
Pumping speed (60 Hz): 48 m³/h
Environmentally friendly:
Quiet
Vibration-free operation Energy-saving
Energy-saving:
Low power consumption
Low heat emission
Modern vacuum technology:
High pumping speed up to ultimate pressure
Low final pressure, even with gas ballast
High water vapor compatibility
Continuous operation even at 1000 mbar
Built-in oil pump, force-lubricated slide bearings
Minimal air loss
High leak tightness (4He-capable)
Technical data:
Product: TRIVAC D 40 B
Connection flange suction side: DN 40 ISO-KF
Connection flange pressure side: DN 40 ISO-KF
Nominal pumping speed at 50 Hz: 46.0 m3/h
Nominal pumping speed at 60 Hz: 55.0 m3/h
Pumping speed at 50 Hz: 40.0 m3/h
Pumping speed at 60 Hz: 48.0 m3/h
Final partial pressure without gas ballast: 1.0 x 10-4 mbar
Final total pressure without gas ballast: < 2.0 x 10-3 mbar
Final total pressure with gas ballast: < 5.0 x 10-3 mbar
Water vapor compatibility at 50 Hz: 40.0 mbar
Water vapor compatibility at 60 Hz: 40.0 mbar
Water vapor capacity at 50 Hz: 1,184 g/h
Water vapor capacity at 60 Hz: 1,184 g/h
Operating fluid quantity
min.: 1.7 l
max.: 2.6 l
Sound level according to DIN 45 635
without gas ballast: 57 db(A)
with gas ballast: 59 db(A)
Mains connection: 3-ph, 200 / 200-240 / 380-400 V ±10%, 50 Hz
3-ph, 200-240 / 380-480 V ±10%, 60 Hz
Motor power: 2.2 kW
Motor speed at 50 Hz: 1,430 min-1
Motor speed at 60 Hz: 1,735 min -1
Motor protection class: IP 55
Permissible ambient temperature: +12 to +40°C
Weight: 73.0 kg
Type: Trivac D 40 B
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate test chamber 2500 liters
VötschVC 4200/S -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC 4200/S
Climate test chamber 2500 liters water-cooled
Temperature test:
Temperature range -40°C to + 180°C
Temperature deviation in time: ± 0.3 to ± 1.0
Spatial temperature deviation: ± 1.0 to ± 2.0
Temperature gradient 2 to 4
Heating speed: 2.0 K/min
Cooling rate: 3.0 K/min
Climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation over time: ± 0.1 to ± 0.5
Temperature deviation over time: ± 1 to ± 1.5
Temperature gradient 2 to 3
Humidity range: 10% to 98% r.h.
Humidity deviation over time: + 1 to 3 % r.h.
Dew point range +5 to +89°C
Test room dimensions: Width approx. 2000 mm x depth 1150 mm x height 1150 mm
External dimensions: Width approx. 3500 mm x depth 1450 mm x height 2100 mm
Nominal voltage 3/N/PE AC 400 V ±10%50Hz
Rated power 13 kW
Nominal current 21 A
Cgshx Dnksu Au Uto Tet
Refrigerant R-452A
Weight approx. 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Werktuigen

Listing

7,623 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Cgehx Dnsu Nh Rbok Tot
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Temperature cabinet 335 liters
WeissWT3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 3.2 K/min
Cooling: 4.0 K/min
Heat compensation max. 2300 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Cgohx Dnkorbigfe Tot
Rated current: 14 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Cgshx Dnsru Dzusk Tet
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

7,623 km
Climate chamber 38m³ Sunlight simulation
WeissWK 40'/40-120/So -40° bis +120°C
Call
Condition: excellent (used), Internal dimensions (net) H approx. 2150 mm W approx. 3000 mm D approx. 6000 mm
Air circulation system (on chamber rear wall) Width approx. 800 mm
External dimensions with machine unit and without control cabinets
Height approx. 3360 mm Width approx. 3320 mm Depth approx. 8620 mm
Machine room, attached to the rear wall of the chamber
Height approx. 2340 mm Width approx. 3320 mm Depth approx. 1500 mm
Electrical control cabinet, mounted on the side of the base frame
Height approx. 2340 mm Width approx. 2400 mm Depth approx. 600 mm
Chamber door (double-leaf)
Height approx. 2150 mm Width approx. 3000 mm
Pedestrian door (single-leaf)
Height approx. 1900 mm Width approx. 900 mm
Lighting (switch next to pedestrian door)
4 incandescent lamps 60W
Feed-throughs 4 pcs. 125 mm ∅
Floor load capacity
30,000 N/m² (surface load);
2,500 N per polyamide wheel Ø100mm;
4,000 N for a wheel with 4 cm²
Ceiling opening (clear dimensions of the lower disk)
Length approx. 600 mm Width approx. 700 mm
Quantity: 10 pieces
Ceiling load: 10 SoSi radiators + 1 person 90 kg
Working temperature range:
Cgshx Dnkjtrmm Nj Tst
Temperature range -40 °C ... +120 °C (discontinuous)
Cooling speed:
approx. 1 K/min. linear from 80°C to -40°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
At temperatures < (-20°C) the recirculated air volume is reduced by 50%.
(e.g. PV 1200)
Heating speed:
approx. 1 K/min. linear from -30°C to +90°C with test specimen mass and without thermal load,
measured in the air outlet of the air circulation system.
(e.g. PR 308.2)
Test specimen mass: 600 kg aluminum (vehicle - partial body)
Working range climate without sunlight simulation:
Temperature range: +10 °C ...+95 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Temperature constancy: ≤ ± 2 K (spatial)
Humidity range: 20 ... 80 % r.h., without thermal load
Dew point temperature range: -2 °C ...85 °C without thermal load
Climate working range with sunlight simulation:
Temperature range: +23 °C ...+50 °C
Temperature constancy: ≤ ± 0.5 K (temporal)
Humidity range: 20 ... 70 % r.h., with thermal load
Dew point temperature range: -2 °C ...43 °C without thermal load
Thermal load of the SoSi: Max. 10 kW
Temperature and humidity instances:
Temperature
The following maximum deviation is specified for the temperature in the climate and temperature range
(including measurement uncertainty and with test material):
Blow-out after 15 minutes: ±1K
Intake after 45 minutes: ±1.5K (external sensor)
Humidity
For the relative humidity at the operating point 80°C / 80% r.h.
the following maximum deviation (including measurement uncertainty and with test material) is specified:
Blow-out after 30 minutes: ±3% r.h.
Intake after 60 minutes: ±3% r.h. (external sensor)
Connection and consumption data:
Air-cooled refrigeration unit, maximum air temperature +38°C
Refrigerant R 404 A and R23
Water supply for humidifier:
Approx. 40 l/h = 40 kg/h installed steam output,
demineralized water, electrical conductivity 5-20 μS/m
Mains connection: 400 V; 3 PH + N + PE; 50 Hz
Connected load: 250 kVA, 350 A
Connection according to VDE 0110 group 2: 5x185 mm2 CU
On-site fuse protection: 355 A
Air circulation volume (FI-controlled): 24,000 to 28,000 m³/h
FC basic setting: 50% (achievement of the parameters)
Technical data solar simulation:
Manufacturer: BF Engineering GmbH
Type: G-BEM-1119
Number of lights: EPSU 2 x 2k_HQI
Ballast: 10
Ignitor: IGC-4k-03
Light source: OSRAM HQI 2000W High Flux
3〜/ N / PE
We make it easier for you to find: "tabe agb-40"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Tabe Agb-40 (58,492)
Search Werktuigen now with more than 200,000 used machines:
Find out now
+49 201 857 86 180
+49 201 857 86 180
Create listing
*per listing / month