GeneratorFOGO
FD250 I-ST
Generator
FOGO
FD250 I-ST
EXW ONO plus VAT
€31,800
Year of construction
2023
Condition
New
(fully functional)
Location
Hofstetten 

Machine data
- Machine type:
- Generator
- Manufacturer:
- FOGO
- Model:
- FD250 I-ST
- Machine number:
- D 26721
- Year of construction:
- 2023
- Condition:
- new
- Functionality:
- fully functional
- Operating hours:
- 1 h
Price & Location
EXW ONO plus VAT
€31,800
- Location:
- Hofstetten 10/2, 3243 Ruprechtshofen, Österreich

Call
Technical details
- Fuel type:
- diesel
- Tank capacity:
- 450 l
- Color:
- grey-black
- Power:
- 244 kW (331.75 HP)
- Output current:
- 400 A
- Output voltage:
- 400 V
- Output frequency:
- 50 Hz
- Type of output current:
- AC
- Nominal power:
- 220 kW (299.12 HP)
- Nominal power (apparent):
- 275 kVA
- Continuous power:
- 200 kW (271.92 HP)
- Continuous power (apparent):
- 250 kVA
- Total length:
- 3,660 mm
- Total width:
- 115 mm
- Total height:
- 2,100 mm
- Rotational speed (max.):
- 1,500 rpm
- Type of cooling:
- water
- Equipment:
- CE marking
Details about the offer
- Listing ID:
- A222-90127
- Update:
- 08.07.2026
Description
## FOGO Generator Set 250/275 kVA – Sound-Insulated – Iveco Engine – Leroy Somer Generator
### Manufacturer
FOGO
### Engine
* Manufacturer: Iveco (Italy)
* Model: NEF67TE8P
Dodpfx Aiozki Atotjkp
* Emission Standard: Stage II
* 6-cylinder diesel engine
* Water-cooled
* Power: 244 kW at 1,500 rpm
### Generator
* Manufacturer: Leroy Somer (France)
* Power: 250 / 275 kVA
* Voltage: 230 / 400 V
* Frequency: 50 Hz
* AVR voltage regulation
### Control System
ComAp InteliLite4 AMF25
* Digital control and start unit
* Automatic mains monitoring (AMF)
* Automatic start function
* Display of voltage, current, frequency, and power (kW)
* Engine monitoring
* Operating hour counter
* Maintenance interval display
* Integrated battery charger
### Technical Data
* Dimensions (L × W × H): 370 × 116 × 193 cm
* Weight: 1,980 kg
* Fuel tank capacity: 450 liters
* Sound level: approx. 70 dB(A) at a distance of 7 m
* Fuel consumption:
* 24.9 l/h at 50% load
* 36.4 l/h at 75% load
* Integrated spill containment basin: approx. 150 liters
### Notes
* Sale does not include connection cables. The cables shown in the pictures are only for testing purposes.
### Display Messages
Maintenance / Service
* The maintenance indicator is based on the factory-set operating hours and days. Since the engine still contains the initial oil, the maintenance indicator can, of course, be reset upon request.
Warning Charger
* This message appears because the integrated battery charger and the engine/coolant preheating system are not currently connected to an external 230 V power supply. The message will disappear after connecting the mains power supply.
Inspection and test runs are possible at any time by appointment.
If you have any further questions, please do not hesitate to contact us by phone or message.
The listing was translated automatically. Translation errors are possible.
### Manufacturer
FOGO
### Engine
* Manufacturer: Iveco (Italy)
* Model: NEF67TE8P
Dodpfx Aiozki Atotjkp
* Emission Standard: Stage II
* 6-cylinder diesel engine
* Water-cooled
* Power: 244 kW at 1,500 rpm
### Generator
* Manufacturer: Leroy Somer (France)
* Power: 250 / 275 kVA
* Voltage: 230 / 400 V
* Frequency: 50 Hz
* AVR voltage regulation
### Control System
ComAp InteliLite4 AMF25
* Digital control and start unit
* Automatic mains monitoring (AMF)
* Automatic start function
* Display of voltage, current, frequency, and power (kW)
* Engine monitoring
* Operating hour counter
* Maintenance interval display
* Integrated battery charger
### Technical Data
* Dimensions (L × W × H): 370 × 116 × 193 cm
* Weight: 1,980 kg
* Fuel tank capacity: 450 liters
* Sound level: approx. 70 dB(A) at a distance of 7 m
* Fuel consumption:
* 24.9 l/h at 50% load
* 36.4 l/h at 75% load
* Integrated spill containment basin: approx. 150 liters
### Notes
* Sale does not include connection cables. The cables shown in the pictures are only for testing purposes.
### Display Messages
Maintenance / Service
* The maintenance indicator is based on the factory-set operating hours and days. Since the engine still contains the initial oil, the maintenance indicator can, of course, be reset upon request.
Warning Charger
* This message appears because the integrated battery charger and the engine/coolant preheating system are not currently connected to an external 230 V power supply. The message will disappear after connecting the mains power supply.
Inspection and test runs are possible at any time by appointment.
If you have any further questions, please do not hesitate to contact us by phone or message.
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Last online: Yesterday
Registered since: 2026
1 listing online
Send inquiry
Telephone & Fax
+43 664 4... show
Your listing has been deleted successfully
An error has occurred